This study examined correlations between radon, thoron and thoron progeny concentrations based on surveys conducted in several different countries. For this purpose, passive detectors developed or modified by the National Institute of Radiological Sciences (NIRS) were used. Radon and thoron concentrations were measured using passive discriminative radon-thoron detectors. Thoron progeny measurements were conducted using the NIRS-modified detector, originally developed by Zhuo and Iida. Weak correlations were found between radon and thoron as well as between thoron and thoron progeny. The statistical evaluation showed that attention should be paid to the thoron equilibrium factor for calculation of thoron progeny concentrations based on thoron measurements. In addition, this evaluation indicated that radon, thoron and thoron progeny were independent parameters, so it would be difficult to estimate the concentration of one from those of the others.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3709658PMC
http://dx.doi.org/10.1093/jrr/rrs129DOI Listing

Publication Analysis

Top Keywords

thoron progeny
24
radon thoron
20
thoron thoron
16
thoron
14
correlations radon
8
progeny concentrations
8
concentrations based
8
progeny
6
radon
5
comparative analysis
4

Similar Publications

Radon (Rn) and thoron (Rn) were reported as the highest contributors to natural radiation received by humans. Furthermore, radon has been stated as the second-highest cause of lung cancer. The concentrations of U and Th (the parent nuclide of radon and thoron, respectively) in nature vary with geological conditions and can be enhanced by human activities.

View Article and Find Full Text PDF
Article Synopsis
  • The study assesses radon and thoron exhalation rates using a closed-loop technique with online radon monitors, particularly focusing on the balance of air volume in the sample and detector chambers.
  • An alternative model is proposed that treats the sample and detector chambers as separate entities, refining the mass balance equation to account for air flow rates affecting radon/thoron concentrations.
  • Results indicate that while lower flow rates don't affect long-lived radon buildup, experiments showed that increasing flow rates impacts the effective removal rate of radon, suggesting potential issues with thoron interference at lower flows.
View Article and Find Full Text PDF

222Rn is recognized as a matter of international concern for human health risk. Because 220Rn as well as 222Rn coexist in the natural environment, thoron sometimes influences the experiment for radon measurement. It is important to measure radon and thoron separately to evaluate the risk of the exposure to 222Rn.

View Article and Find Full Text PDF

Assessment of annual effective doses from indoor radon and thoron in Doi Lo, Chiang Mai, Thailand.

Radiat Prot Dosimetry

November 2024

Department of Radiologic Technology, Faculty of Associated Medical Sciences, Chiang Mai University, Chiang Mai 50200, Thailand.

This study aimed to determine the annual effective dose resulting from radon and thoron progeny inhalation. The levels of radon, thoron, and progeny were assessed in residences situated in the Doi Lo region of Chiang Mai, Thailand. Indoor radon and thoron concentrations were detected using passive discriminative detectors.

View Article and Find Full Text PDF

The radon (Rn) and thoron (Tn) concentrations and other environmental parameters were measured in the vicinity of active faults in two regions with different geology structure of Japan. The range of measured values was from 1.2 to 74 kBq m$^{-3}$, 1.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!