The uncemented glenoid implants in total anatomical shoulder arthroplasty are likely to be accused of problems like dissociations, secondary rotator cuff tear, and wear of polyethylene (PE). This work is a clinical and radiological prospective review of 143 cases of anatomical total shoulder arthroplasty using a new metal back uncemented glenoid implant (MB) in order to see if this new implant induces those complications. A total of 143 cases were operated between 2003 and 2011. In a first part, the whole series of 143 cases was radiologically studied in order to quantify the lateralisation induced by the MB implant. In a second study, 37 cases had a mean follow-up of 38 months (24-75, mean 32) and served for the clinical and radiological final study. Pre- and postoperative clinical evaluation was done using the Constant-Murley score and the simple shoulder test from Matsen. The final X-rays served to detect an eventual secondary narrowing of the joint space and to analyse the frequency of radio lucent lines (RLL) and loosenings. Despite a small radiological lateralisation in comparison with the normal contralateral side (0.36 cm, p = 0.02), the clinical results after 2 years were similar to the published cemented glenoid implants series but without any RLL, glenoid loosening or joint narrowing. Some dissociations occured in the beginning and definitely eliminated by a design modification of the PE tray. The discussion tried to show that, despite a still short follow-up, this series is encouraging to continue to use this new MB implant. Different applications of the concept of universality and conversion are discussed, this tray been also the support of a glenosphere in reverse arthroplasty.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3535408 | PMC |
http://dx.doi.org/10.1007/s00590-012-1109-6 | DOI Listing |
Ann Surg
January 2025
Division of Thoracic Surgery, Department of Surgery, University of Toronto, Toronto, Canada.
Objective: To determine the impact of prolonged storage of donor lungs at 10°C of up to 24h on outcome after lung transplantation.
Background: An increasing body of evidence suggests 10°C as the optimal storage temperature for donor lungs. A recent study showed that cold ischemic times can be safely expanded to >12h when lungs are stored at 10°C.
Aliment Pharmacol Ther
January 2025
Université Paris-Saclay, UVSQ, Inserm, Gustave Roussy, CESP, Villejuif, France.
Background: Association between dietary factors and the risk of developing inflammatory bowel disease (IBD) has been studied extensively. However, identification of deleterious dietary patterns merits further study.
Aim: To investigate the risk of developing Crohn's disease (CD) and ulcerative colitis (UC) according to the inflammatory score of the diet (ISD) in the multinational European Prospective Investigation into Cancer and Nutrition (EPIC) cohort.
Spinal Cord
January 2025
Physiotherapy Department, Austin Health, Melbourne, VIC, Australia.
Study Design: Registry-based cohort study.
Objectives: To evaluate the impact of the introduction of a new bladder management model of care at the Victorian Spinal Cord Service (VSCS) on the incidence of subsequent emergency department presentations and readmissions to hospital for urinary tract infection (UTI) in the first 2 years after injury.
Setting: VSCS, Austin Health, Melbourne, Australia.
Int J Colorectal Dis
January 2025
Colorectal Surgery Unit, Department of General and Digestive Surgery, Hospital Clínico Universitario de Valencia, Av. Blasco Ibáñez, 17. 46010, Valencia, Spain.
Purpose: This meta-analysis aims to evaluate the efficacy of powered circular staplers (PCS) compared to manual circular staplers (MCS) in reducing anastomotic leakage (AL) and postoperative bleeding (AB) in colorectal surgery.
Methods: Extensive searches were performed in the Embase, PubMed, and SCOPUS electronic bibliographic databases. Most studies were of an observational nature, and only one randomized clinical trial was identified.
Med J Malaysia
January 2025
Universiti Sains Malaysia, School of Medical Sciences, Department of Ophthalmology and Visual Science, Health Campus, Kubang Kerian, Kelantan, Malaysia.
Introduction: Cataract is a leading cause of visual impairment globally and in Malaysia, with surgery being the definitive treatment. While intracapsular cataract extraction (ICCE) is now less commonly performed due to advancements in surgical techniques, it remains essential in specific cases, such as those with weak zonular support. This study aims to evaluate the incidence, clinical profiles, and visual outcomes of patients who underwent ICCE, with or without intraocular lens (IOL) implantation, at Hospital Melaka, Malaysia, over the past decade.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!