A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A comparative evaluation of dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion - An ex vivo study. | LitMetric

Background And Objective: Enormous advances have been made in adhesives; however, the problem of post-operative sensitivity has dragged along. Enough literature exists on the effect of air abrasion over bond strength of composites. However, not much is reported on its relation with microleakage and post operative sensitivity. Therefore, the aim of the study was to compare and evaluate dentinal hypersensitivity and microleakage associated with composite restorations in cavities preconditioned with air abrasion.

Study Design: Fifteen patients were selected for the study who had to undergo extractions of both maxillary first premolars. On each patient, occlusally placed Class V cavities were made using rotary burs on both the premolars. On the right side premolar, restoration was done using total etch technique. On the left side premolar, restoration was done in similar way after preconditioning of the cavity with air abrasion. Sensitivity levels were recorded on a modified visual analogue scale preoperatively and post operatively at 1 week and one month time period. Following extraction, dye penetration test was done and 1 sample each from one group was subjected to Scanning Electron Microscope for evaluation of tooth restoration interface.

Results: Clinically significant difference was there in post operative sensitivity levels after one month between the two groups. Increase in sensitivity was less in teeth restored after preconditioning with air abrasion. Dye penetration was also less in teeth restored after preconditioning with air abrasion. However, penetration at the gingival wall was more than the occlusal wall in both the groups.

Conclusion: The study consolidates the fact that microleakage and post operative sensitivity are linked directly. It also proves that air abrasion can help in reducing the post operative sensitivity to a level; however, a larger sample size would be needed to obtain more robust results with stronger validation.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3532794PMC
http://dx.doi.org/10.4103/0976-237X.103624DOI Listing

Publication Analysis

Top Keywords

air abrasion
24
post operative
16
operative sensitivity
16
dentinal hypersensitivity
8
hypersensitivity microleakage
8
microleakage associated
8
associated composite
8
composite restorations
8
restorations cavities
8
cavities preconditioned
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!