Objective: To assess the incidence of recurrent stress urinary incontinence (SUI) following vaginal excision of exposed mid-urethral tape (MUT).

Study Design: This was a retrospective observational study in a tertiary urogynaecology unit of an inner city teaching hospital. The population consisted of 41 consecutive women seen with a vaginal mesh exposure following MUT insertion between 2000 and 2009, which failed to resolve with conservative measures. The primary outcome measure was the presence of symptoms of stress urinary incontinence following surgical excision of exposed mesh.

Results: The incidence of recurrent SUI following tape excision was 34.1%. Type of mid-urethral tape, menopausal status, and the time interval between tape insertion and excision were not found to be significantly associated with the risk of recurrent SUI.

Conclusions: Over a third of women experience recurrent SUI after surgical management of vaginal mesh exposure following MUT insertion. Risk factors may be more comprehensively studied using prospectively collected cohorts.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejogrb.2012.11.013DOI Listing

Publication Analysis

Top Keywords

vaginal mesh
12
mesh exposure
12
mid-urethral tape
12
tape insertion
8
incidence recurrent
8
stress urinary
8
urinary incontinence
8
excision exposed
8
exposure mut
8
mut insertion
8

Similar Publications

Introduction And Hypothesis: The aim of the study was to compare clinical outcomes when using robotic-assisted sacral hysterocolpopexy (RASC) and vaginal surgery using the Uphold™ Vaginal Support System mesh for pelvic organ prolapse repair.

Methods: This was a nonrandomized, prospective, multicenter study in which 72 women underwent RASC, and 73 Uphold™ surgery, for apical prolapse (POP-Q C ≥ stage II). Anatomical outcomes were assessed using the Pelvic Organ Prolapse Quantification (POP-Q) system.

View Article and Find Full Text PDF
Article Synopsis
  • The study compares total laparoscopic hysterectomy (TLH) and laparoscopic supracervical hysterectomy (LSCH) during minimally invasive sacrocolpopexy for treating uterovaginal prolapse.
  • Results showed no significant difference in overall recurrence of prolapse between the two methods, but TLH had lower odds of recurrence in multivariable analysis.
  • TLH had a higher proportion of mesh exposures with lightweight mesh, but this finding wasn't significant after adjusting for other factors.
View Article and Find Full Text PDF

Robot-Assisted Laparoscopic Sacrohysteropexy with Autologous Fascia Lata.

Int Urogynecol J

December 2024

Department of Obstetrics and Gynaecology, Monash University, Clayton, VIC, 3168, Australia.

Introduction And Hypothesis: Autologous fascia lata has been increasingly utilised in pelvic floor reconstructive surgeries such as sacrocolpopexy and sacrohysteropexy. This case highlights sacrohysteropexy with autologous fascia lata as a promising option for women with advanced uterovaginal prolapse who wish to preserve their uterus and avoid synthetic mesh.

Methods: We report the case of a 65-year-old woman with stage 3 pelvic organ prolapse following one forceps and one spontaneous vaginal delivery.

View Article and Find Full Text PDF

Background: Stress urinary incontinence is a frequent condition in female patients. Surgical treatment with tension-free vaginal tape (TVT) insertion is a minimally invasive option with immediate improvement of symptoms. Different possible complications have been described in the literature.

View Article and Find Full Text PDF

Mechanical non-conformance of conventionally used transvaginal non-degradable meshes has led to complications like organ perforation, dyspareunia caused by mesh stiffness, and stress shielding. In this study, we have solved the dire need of mimicking the mechanical properties of vaginal wall by designing and developing a soft and elastic mesh made of polycaprolactone (PCL), citric acid modified polyethylene glycol (PEGC) and zinc oxide (ZnO) prepared through electrospinning and is tested in-vitro and in-vivo. Mesh containing 90:10:0.

View Article and Find Full Text PDF