A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Determination of patulin in juice by ultra performance liquid chromatography-tandem mass spectrometry]. | LitMetric

A method was developed for the simultaneous determination of patulin in juice by solid phase extraction (SPE)-ultra performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry (UPLC-ESI-MS/MS). The cloudy juice was hydrolyzed by enzyme and extracted by ethyl acetate. The extract of cloudy juice was then enriched and purified by an HLB SPE cartridge. If the juice was clear it was directly treated by the cartridge as above. The separation was performed on a C18 column with the gradient elution of acetonitrile and water. The patulin was detected by MS with electrospray negative ionization (ESI-) in the mode of multiple reaction monitoring (MRM). The good linearity was observed in the range of 1.0 - 500 microg/L with the correlation coefficient of 0. 999 and the limit of quantitation of 5.0 microg/kg. The recoveries were in the range of 80. 6% -91. 8% at three spiked levels of 5.0, 25.0 and 100.0 microg/kg with the relative standard deviations of 1.5% -7.3%. It was proved to be a simple, reliable and accurate method which can fully meet the requirements of patulin detection in juice samples according to most domestic and international legislations.

Download full-text PDF

Source
http://dx.doi.org/10.3724/sp.j.1123.2012.04026DOI Listing

Publication Analysis

Top Keywords

patulin juice
8
performance liquid
8
cloudy juice
8
juice
6
[determination patulin
4
juice ultra
4
ultra performance
4
liquid chromatography-tandem
4
chromatography-tandem mass
4
mass spectrometry]
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!