Allergens and other pollutants in house dust are collected using a variety of dust samplers that are assumed to operate similarly. This factorial design study compared sampler performance under controlled environmental conditions. House dust with known particle sizes (212-90, 90-45, and <45 μm) and allergen concentrations were sampled from new carpet squares with varying denier, pile height and pile densities. Dust mass and allergen recovery for total dust mites (Der p 1 and Der f 1), cat (Fel d 1) and cockroach allergen (Bla g 1) were assessed using the Eureka Mighty Mite (EURK), the High Volume Small Surface Sampler (HVS), or the American Industrial Hygiene Association (AIHA) method. Allergen concentrations were quantified using enzyme-linked immunosorbent assays, and dust mass results were corrected for carpet fiber shedding. Samplers were compared by exploring mass collection efficiency (CE=fiber corrected dust mass/applied dust mass) and concentration ratio (CR=allergen concentration in collected sample/allergen concentration in test dust). Test dust allergen concentrations varied by particle size fraction due to varying laboratory performance over time. The EURK and HVS samplers had CEs of 41-63% in the small and medium particle size fractions, and collected less than 20% of the available dust from the large size fraction. The AIHA CE ranged from 10% to 17% in the medium and small particle size fractions, but collected little dust in the largest particle size fraction. The AIHA and HVS samplers were more likely to acquire more representative and less variable allergen CRs compared with the EURK method. Health studies that use allergen concentration as an exposure metric need to consider the implications of sampler performance when interpreting links to health outcomes and development of health-based standards for allergens in house dust.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1038/jes.2012.112 | DOI Listing |
Sci Rep
January 2025
Department of Aeronautical and Astronautical Engineering, Korea Aerospace University, Goyang, 10540, Republic of Korea.
The buildup of dust on solar panels has significantly reduced the operational lifespan and mission performance of exploration rovers, and traditional dust removal techniques have proven inadequate for the Martian environment. The present study proposes a novel method for removing dust from the solar panels of Mars exploration rovers using Chladni patterns, addressing the persistent issue of efficiency loss due to Martian dust accumulation. To overcome these challenges, the proposed method leveraged Chladni patterns, generated by specific frequencies, to effectively clear dust from the panels.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Civil Engineering , University of Engineering and Technology Peshawar, Peshawar, Pakistan.
For millennia mud has been utilized to make brick for the construction of both residential as well as architectural purposes. However, concerns regarding their vulnerability to different kinds of hazards due to their weak mechanical properties and durability have emerged. This study addressed the global challenge of developing sustainable and affordable construction materials, particularly in resource-constrained regions.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Bioscience and Biotechnology, Konkuk University, Seoul, 05029, Republic of Korea.
Exposure to particulate matter (PM) in the air harms human health. Most studies on particulate matter's (PM) effects have primarily focused on respiratory and cardiovascular diseases. Recently, IL-32θ, one of the IL-32 isoforms, has been demonstrated to modulate cancer development and inflammatory responses.
View Article and Find Full Text PDFRespirology
January 2025
School of Health and Biomedical Sciences, RMIT University, Melbourne, Victoria, Australia.
Background And Objective: Asthma-COPD overlap (ACO) is characterized by patients exhibiting features of both asthma and COPD. Currently, there is no specific treatment for ACO. This study aimed to investigate the therapeutic potential of targeting CD131, a shared receptor subunit for IL-3, IL-5 and GM-CSF, in ACO development and in preventing acute viral exacerbations.
View Article and Find Full Text PDFJ Bras Pneumol
January 2025
. Departamento de Biologia Geral, Universidade Federal Fluminense, Niterói (RJ) Brasil.
Objective: Silicosis is a pneumoconiosis characterized by fibrosis of the lung parenchyma caused by the inhalation of silica particles. Silica dust inhalation is associated with inflammation and induction of oxidative stress in the lungs. This oxidative stress affects telomeres, which are short tandem DNA repeats that cap the end of linear chromosomes.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!