AI Article Synopsis

  • This study examined the effectiveness of high-definition white light endoscopy (hWLE) and narrow band imaging (NBI) in distinguishing between tiny colorectal polyps (≤ 5 mm), which account for 80% of colon polyps.
  • Eight endoscopists evaluated 100 video recordings of polyps (some hyperplastic, some adenomatous) using both hWLE and NBI, with NBI showing improvements in accuracy from 68.8% to 91.3% after training.
  • The results indicated that NBI could achieve similar accuracy levels as hWLE for differentiating polyps, with better interobserver agreement, making it a useful tool for end

Article Abstract

Background And Aim: Diminutive polyps measuring ≤ 5 mm in size constitute 80% of polyps in the colon. We prospectively assessed the performance of high-definition white light endoscopy (hWLE) and narrow band imaging (NBI) in differentiating diminutive colorectal polyps.

Methods: In this prospective, multicenter study, videos of 50 diminutive polyps (31 hyperplastic, 19 adenomatous) in hWLE followed by NBI (total 100 videos) were initially obtained and placed in random order into five separate folders (each folder 20 videos). Eight endoscopists were then invited to predict the histology (each endoscopist 100 videos, 800 video assessments in all). Polyps were classified into types 1-3 (hyperplastic) and type 4 (adenoma). Feedback on individual performance was given after each folder (20 videos) was assessed.

Results: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy in differentiating hyperplastic from adenomatous polyps by hWLE (400 videos) and NBI (400 videos) were 67.8%, 90.7%, 81.7%, 82.1%, and 82.0%; and 82.2%, 81.5%, 73.1%, 88.2%, and 81.8%, respectively. In the pretest and post-test analysis, the accuracy with NBI improved markedly from 68.8% to 91.3% (P = 0.001) compared with hWLE, 76.3-78.8% (P = 0.850). Overall, the interobserver agreement was 0.46 for hWLE (moderate) and 0.64 for NBI (good).

Conclusions: NBI was as accurate as hWLE in differentiating diminutive colorectal polyps. Once a learning curve was reached, NBI achieved significantly higher accuracies with good interobserver agreement. Using a simplified classification, a didactic learning session and feedback on performance, diminutive colorectal polyps could be predicted with high accuracies with NBI.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jgh.12098DOI Listing

Publication Analysis

Top Keywords

diminutive colorectal
16
narrow band
8
band imaging
8
high-definition white
8
white light
8
light endoscopy
8
diminutive polyps
8
nbi
8
differentiating diminutive
8
hyperplastic adenomatous
8

Similar Publications

Colonic polypectomy in 2024: hot or cold?

Acta Gastroenterol Belg

January 2025

Department of Gastroenterology and Hepatology, Ghent University Hospital, Ghent, Belgium.

Colorectal cancer (CRC) is the second and third leading cause of cancer death in men and women respectively worldwide. Colonoscopy is the gold standard screening test to detect premalignant lesions with endoscopic polypectomy preventing evolution to CRC. Endoscopic polypectomy is effective with a higher safety profile and is less costly as compared to surgery.

View Article and Find Full Text PDF

Background And Aims: Accurate measurement of polyp size during colonoscopy is crucial for informing clinical decisions such as resection techniques and surveillance scheduling. This study aimed to compare polyp size measurement accuracy when using a virtual scale endoscope (VSE) or snare-based polyp size measurement.

Methods: This randomized controlled trial enrolled 221 patients undergoing screening, surveillance or diagnostic outpatient colonoscopies.

View Article and Find Full Text PDF

Blastocystis is a ubiquitous waterborne parasite that has been implicated in some disease conditions including colorectal cancer and irritable bowel syndrome, and its surface coat characteristics have been associated with its pathogenicity. Although the morphology of Blastocystis isolates from human and animal sources have been studied, there is a paucity of data on the surface ultrastructure of Blastocystis isolated from water sources. Therefore, this study aimed to determine the occurrence and the ultrastructural surface of Blastocystis isolates from several water sources in Kedah and Penang, Malaysia.

View Article and Find Full Text PDF

Computer-aided diagnosis for the resect-and-discard strategy for colorectal polyps: a systematic review and meta-analysis.

Lancet Gastroenterol Hepatol

November 2024

Department of Biomedical Sciences, Humanitas University, Pieve Emanuele, Italy; Endoscopy Unit, Humanitas Clinical and Research Center, IRCCS, Rozzano, Italy.

Article Synopsis
  • The study explores the use of computer-aided diagnosis (CADx) in the resect-and-discard strategy for the optical diagnosis of diminutive polyps during colonoscopy, aiming to improve diagnosis and reduce unnecessary pathology assessments.
  • It involved a systematic review of existing research to analyze the effectiveness of CADx systems compared to traditional histology for small polyps (≤5 mm), including comparisons of CADx-assisted and unassisted methods.
  • The meta-analysis included 11 studies with a total of 7400 polyps examined, highlighting the potential benefits and harms of using CADx in terms of accurate diagnosis and avoidance of false positives/negatives.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!