AI Article Synopsis

  • Using propylene carbonate (PC) and ethanol (EtOH) as a replacement for acetonitrile (ACN) in liquid chromatography is a greener option for pharmaceutical applications, showing no significant loss in chromatographic performance.
  • This alternative has been validated across different separation methods including reverse phase, ion pair formation, and hydrophilic interaction liquid chromatography without compromising elution order or peak quality.
  • The study also compared thermodynamic parameters and assessed the potential for more eco-friendly sample preparation through large volume injections, indicating minor differences in thermodynamics when switching solvents.

Article Abstract

Substitution of acetonitrile (ACN) as organic modifier in mobile phases for liquid chromatography by mixtures of propylene carbonate (PC) and ethanol (EtOH) may be considered a greener approach for pharmaceutical applications. Such a replacement is achievable without any major compromise in terms of elution order, chromatographic retention, efficiency and peak symmetry. This has been equally demonstrated for reverse phase (RP), ion pair formation (IP) and hydrophilic interaction liquid chromatography (HILIC) separation modes. The impact on the sensitivity induced by the replacement between these organic solvents is discussed for UV-vis and mass spectrometric detection. A comparison between Van Deemter plots obtained under elution conditions based on ACN and PC/EtOH is presented. The alternative elution modes were also compared in terms of thermodynamic parameters, such as standard enthalpy (ΔH⁰) and entropic contributions to the partition between the mobile and the stationary phases, for some model compounds. Van't Hoff plots demonstrated that differences between the thermodynamic parameters are minor when shifting from ACN/water to PC/EtOH/water elution on an octadecyl chemically modified silicagel stationary phase. As long as large volume injection (LVI) of diluents non-miscible with the mobile phase is a recently developed topic having a high potential of greening the sample preparation procedures through elimination of the solvent evaporation stage, this feature was also assessed in the case of ACN replacement by PC/EtOH.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2012.11.045DOI Listing

Publication Analysis

Top Keywords

liquid chromatography
12
pharmaceutical applications
8
organic modifier
8
modifier mobile
8
mobile phases
8
thermodynamic parameters
8
greening pharmaceutical
4
applications liquid
4
chromatography propylene
4
propylene carbonate-ethanol
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!