A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of the trade-off between force attenuation and balance impairment in the design of compliant safety floors. | LitMetric

Safety floors (also known as compliant floors) may reduce the risk of fall-related injuries by attenuating impact force during falls, but are only practical if they do not negatively affect balance and mobility. In this study, we evaluated seven safety surfaces based on their ability to attenuate peak femoral neck force during simulated hip impacts, and their influence on center of pressure (COP) sway during quiet and tandem stance. Overall, we found that some safety floors can attenuate up to 33.7% of the peak femoral impact force without influencing balance. More specifically, during simulated hip impacts, force attenuation for the safety floors ranged from 18.4 (SD 4.3)% to 47.2 (3.1)%, with each floor significantly reducing peak force compared with a rigid surface. For quiet stance, only COP root mean square was affected by flooring (and increased for only two safety floors). During tandem stance, COP root mean square and mean velocity increased in the medial-lateral direction for three of the seven floors. Based on the substantial force attenuation with no concomitant effects on balance for some floors, these results support the development of clinical trials to assess the effectiveness of safety floors at reducing fall-related injuries in high-risk settings.

Download full-text PDF

Source
http://dx.doi.org/10.1123/jab.29.5.563DOI Listing

Publication Analysis

Top Keywords

safety floors
24
force attenuation
12
floors
9
fall-related injuries
8
impact force
8
peak femoral
8
simulated hip
8
hip impacts
8
tandem stance
8
stance cop
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!