A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Do surface electromyograms provide physiological estimates of conduction velocity from the medial gastrocnemius muscle? | LitMetric

Do surface electromyograms provide physiological estimates of conduction velocity from the medial gastrocnemius muscle?

J Electromyogr Kinesiol

Laboratorio di Ingegneria del Sistema Neuromuscolare (LISiN), Politecnico di Torino, Italy.

Published: April 2013

Muscle fiber conduction velocity (CV) is commonly estimated from surface electromyograms (EMGs) collected with electrodes parallel to muscle fibers. If electrodes and muscle fibers are not located in parallel planes, CV estimates are biased towards values far over the physiological range. In virtue of their pinnate architecture, the fibers of muscles such as the gastrocnemius are hardly aligned in planes parallel to surface electrodes. Therefore, in this study we investigate whether physiological CV estimates can be obtained from the gastrocnemius muscle. Specifically, with a large grid of 16×8 electrodes we map CV estimates over the whole gastrocnemius muscle while eleven subjects exerted isometric plantar flexions at three different force levels. CV was estimated for couples of single differential EMGs and estimate locations (i.e., channels) were classified as physiological and non-physiological, depending on whether CV estimates were within the physiological range (3-6ms(-1)) or not. Physiological CV values could be estimated from a markedly small muscle region for eight participants; channels providing physiological CV estimates corresponded to about 5% of the total number of channels. As expected, physiological and non-physiological channels were clustered in distinct regions. CV estimates within the physiological range were obtained for the most distal gastrocnemius portion (ANOVA, P<0.001), where occurrences of propagating potentials were often verified through visual analysis. For the first time, this study shows that CV might be reliably assessed from surface EMGs collected from the most distal gastrocnemius region.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jelekin.2012.11.007DOI Listing

Publication Analysis

Top Keywords

physiological estimates
12
physiological range
12
physiological
9
surface electromyograms
8
conduction velocity
8
muscle fibers
8
estimates gastrocnemius
8
gastrocnemius muscle
8
physiological non-physiological
8
estimates physiological
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!