A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Novel Validated Stability-Indicating UPLC Method for the Estimation of Naproxen and its Impurities in Bulk Drugs and Pharmaceutical Dosage Form. | LitMetric

Novel Validated Stability-Indicating UPLC Method for the Estimation of Naproxen and its Impurities in Bulk Drugs and Pharmaceutical Dosage Form.

Sci Pharm

Dr. Reddy's Laboratories Ltd. IPDO, Bachupally, Hyderabad-500072, A.P, India. ; Department of Chemistry, J. N. T. University, Kukatpally, Hyderabad-500072, A.P, India.

Published: December 2012

A novel, reversed-phase ultra-performance liquid chromatographic method was developed and validated for the determination of related substances in Naproxen (NAP) bulk drugs and dosage forms. The related substances included degradation and process-related impurities. The method was developed using the Waters Acquity BEH C18 column using the gradient program with mobile phase A of a pH 7.0 phosphate buffer and methanol in the ratio of 90: 10 (v/v) and mobile phase B as methanol and acetonitrile in the ratio of 50:50 (v/v). Naproxen and its impurities were monitored at 260 nm. Naproxen was subjected to the stress conditions of oxidative, acid, base, hydrolytic, thermal, humidity, and photolytic degradations. The degradation products were well-resolved from the main peak and its impurities, proving the stability-indicating power of the method. The performance of the method was validated according to the present ICH guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness, and robustness.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3528050PMC
http://dx.doi.org/10.3797/scipharm.1207-12DOI Listing

Publication Analysis

Top Keywords

naproxen impurities
8
bulk drugs
8
method developed
8
mobile phase
8
method
5
novel validated
4
validated stability-indicating
4
stability-indicating uplc
4
uplc method
4
method estimation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!