Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: To compare whole-body magnetic resonance (MR) imaging with conventional imaging for detection of distant metastases in pediatric patients with common malignant tumors.
Materials And Methods: This institutional review board-approved, HIPAA-compliant, multicenter prospective cohort study included 188 patients (109 male, 79 female; mean age, 10.2 years; range, < 1 to 21 years) with newly diagnosed lymphoma, neuroblastoma, or soft-tissue sarcoma. Informed consent was obtained and all patients underwent noncontrast material-enhanced whole-body MR imaging and standard-practice conventional imaging. All images were reviewed centrally by 10 pairs of readers. An independent panel verified the presence or absence of distant metastases. Detection of metastasis with whole-body MR and conventional imaging was quantified by using the area under the receiver operating characteristic curve (AUC). The effects of tumor subtype, patient age, and distant skeletal and pulmonary disease on diagnostic accuracy were also analyzed.
Results: Of the 134 eligible patients, 66 (33 positive and 33 negative for metastasis) were selected for image review and analysis. Whole-body MR imaging did not meet the noninferiority criterion for accuracy when compared with conventional imaging for detection of metastasis (difference between average AUCs was -0.03 [95% confidence interval: -0.10, 0.04]); however, the average AUC for solid tumors was significantly higher than that for lymphomas (P = .006). More skeletal metastases were detected by using whole-body MR imaging than by using conventional imaging (P = .03), but fewer lung metastases were detected (P < .001). Patient age did not affect accuracy.
Conclusion: The noninferior accuracy for diagnosis of distant metastasis in patients with common pediatric tumors was not established for the use of whole-body MR imaging compared with conventional methods. However, improved accuracy was seen with whole-body MR imaging in patients with nonlymphomatous tumors.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3558875 | PMC |
http://dx.doi.org/10.1148/radiol.12112531 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!