A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Comparison between the Airtraq, X-Lite, and direct laryngoscopes for thyroid surgery: a randomized clinical trial]. | LitMetric

Purpose: To compare the performance of the Airtraq, X-Lite, and direct laryngoscopes for tracheal intubation for elective thyroid surgery.

Methods: In this randomized prospective study, Patients who were ASA (American Society of Anesthesiologists) I or II physical status I or II and patients undergoing thyroid surgery were included in this randomized prospective study. Patients with attributes for difficult intubation criteria were excluded. After induction of anesthesia with fentanyl, propofol, and cisatracurium, patients were randomized into three groups according to the intubating device used: Airtraq laryngoscope (Airtraq), X-Lite video laryngoscope (X-lLite), and direct laryngoscope with a Macintosh blade (Direct). The primary outcome measurement was the time needed for tracheal intubation. Secondary outcomes included intubation difficulty score (IDS), Cormack-Lehane classification, as well as hemodynamic and respiratory effects.

Results: One hundred and five patients were included. Mean (standard deviation) time for intubation was 28.2 (2.1) sec in the Airtraq group vs 36.6 (3.7) sec in the X-Lite group (P < 0.001), and 41.1 (4.4) sec in the Direct group (P < 0.001). Compared with to the direct laryngoscope, the Airtraq provided better visualization of the glottis (P = 0.003) with fewer attempts (P < 0.001) and lower IDS (P < 0.001). The intubation difficulty score was lower with the Airtraq than with the X-Lite (P = 0.003). Patients in the X-Lite and Direct groups showed more hemodynamic variations than those in the Airtraq group. There was only one failed intubation, in the direct group.

Conclusion: In thyroid surgery, the Airtraq and X-Lite laryngoscopes decrease time to intubation when compared with direct laryngoscopy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s12630-012-9870-xDOI Listing

Publication Analysis

Top Keywords

airtraq x-lite
20
x-lite direct
12
thyroid surgery
12
direct
9
direct laryngoscopes
8
airtraq
8
intubation
8
tracheal intubation
8
randomized prospective
8
prospective study
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!