Download full-text PDF

Source
http://dx.doi.org/10.1001/virtualmentor.2004.6.3.pfor3-0403DOI Listing

Publication Analysis

Top Keywords

improving quality
4
quality safety
4
safety care
4
care loyola
4
loyola university
4
university health
4
health system
4
improving
1
safety
1
care
1

Similar Publications

Is Intracranial Pressure Monitoring After Open Cranial Procedures Associated With Outcome?

J Surg Res

January 2025

Division of Trauma and Critical Care, Department of Surgery, Reading Hospital, West Reading, Pennsylvania. Electronic address:

Introduction: It is unclear if intracranial pressure monitoring (ICPM) after open cranial procedures (craniotomy or craniectomy) (OC) for traumatic brain injury is associated with mortality. We hypothesized that ICPM placed early after OC was associated with lower mortality compared to no ICPM or delayed ICPM placement.

Methods: Using 2020-2021 data from the American College of Surgeons Trauma Quality Improvement Program, patients ≥16 y from level 1 and 2 trauma centers who underwent OC were divided into two groups: ICPM placed within 72 h of OC (early) and no ICPM or ICPM placed after 72 h (none/delayed).

View Article and Find Full Text PDF

Introduction: Surgical site infection (SSI) after lower extremity (LE) bypass surgery is associated with longer length of stay, higher hospital cost, increased morbidity, and even graft loss. Silver impregnated dressings have been used by other surgical subspecialties to decrease SSI with reported success. The National Surgical Quality Improvement Program (NSQIP) published a national expected rate of 7.

View Article and Find Full Text PDF

Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top vs. a tapered top.

Biomed Phys Eng Express

January 2025

Advanced Nuclear Medicine Science, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, JAPAN, Chiba, 263-8555, JAPAN.

For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously.

View Article and Find Full Text PDF

Hemostatic Efficacy of TachoSil in Loop Electrosurgical Excisional Procedure: A Prospective Randomized Controlled Study.

J Low Genit Tract Dis

January 2025

Department of Obstetrics and Gynecology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Republic of Korea.

Objective: The aim of the study was to evaluate the hemostatic efficacy of the fibrin sealant patch (TachoSil) after loop electrosurgical excision (LEEP) and its influence on other complications and quality of life (QoL).

Materials And Methods: This single-blind, prospective, randomized study involved patients undergoing LEEP with or without TachoSil (1:1) between August 2014 and August 2015 in Asan Medical Center, Korea. Primary outcome measures were bleeding duration and the frequency of additional treatment owing to vaginal bleeding within 2 weeks after LEEP.

View Article and Find Full Text PDF

Background: Resilience refers to the ability to adapt or recover from stress. There is increasing appreciation that it plays an important role in wholistic patient-centered care and may affect patient outcomes, including those of orthopaedic surgery. Despite being a focus of the current orthopaedic evidence, there is no strong understanding yet of whether resilience is a stable patient quality or a dynamic one that may be modified perioperatively to improve patient-reported outcome scores.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!