A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Hemodynamic variations due to spiral blood flow through four patient-specific bifurcated stent graft configurations for the treatment of abdominal aortic aneurysms. | LitMetric

Hemodynamic variations due to spiral blood flow through four patient-specific bifurcated stent graft configurations for the treatment of abdominal aortic aneurysms.

Int J Numer Method Biomed Eng

Galway Medical Technologies Centre-GMedTech, Department of Mechanical and Industrial Engineering, Galway Mayo Institute of Technology, Galway, Ireland.

Published: February 2013

Endovascular repair is now a recognised procedure for treating abdominal aortic aneurysms. However, post-operative complications such as stent graft migration and thrombus may still occur. To assess these complications numerically, the correct input boundary conditions, which include the full human aorta with associated branching, should be included. Four patient-specific computed tomography scanned bifurcated stent grafts (SGs) were modelled and attached onto a full human aorta, which included the ascending, aortic arch and descending aortas. Two of the SG geometries had a twisted leg configuration, while the other two had conventional nontwisted leg configurations. Computational fluid dynamics was completed for both geometries and the hemodynamics assessed. The complexity of the flow patterns and secondary flows were influenced by the inclusion of the full human aorta at the SG proximal section. During the decelerating phase significant recirculations occurred along the main body of all SG configurations. The inclusion of the full human aorta did not impact the velocity contours within the distal legs and there was no difference in drag forces with the SG containing the full human aorta and those without. A twisted leg configuration further promoted a spiral flow formation along its distal legs.

Download full-text PDF

Source
http://dx.doi.org/10.1002/cnm.2525DOI Listing

Publication Analysis

Top Keywords

full human
20
human aorta
20
bifurcated stent
8
stent graft
8
abdominal aortic
8
aortic aneurysms
8
twisted leg
8
leg configuration
8
inclusion full
8
distal legs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!