Background: The cobas TaqScreen MPX Test, version 2.0, a multiplex, multi-dye nucleic acid amplification technology (NAT) test from Roche was evaluated by two European Blood Banks, the German Red Cross Blood Donor Service, Frankfurt, Germany and Centro de Hemoterapia y Hemodonación de Castilla y León, Valladolid, Spain. In addition, the cobas TaqScreen DPX Test was evaluated for the simultaneous detection and quantitation of parvovirus B19 and the detection of hepatitis A virus (HAV).

Study Design And Methods: The performances of the two tests were evaluated regarding the analytical sensitivity, the reproducibility of the tests using samples containing low concentrations of each virus and cross-contamination using samples containing high titres of virus.

Results: The analytical sensitivity of the MPX Test, version 2.0, obtained by the German Red Cross Blood Donor Service was 1·1, 3·9 and 43·3 IU/ml for HBV, HCV and HIV-1, respectively. The comparable analytical sensitivity at Centro de Hemoterapia y Hemodonación de Castilla y León was 3·5, 17·6 and 50·6 IU/ml for HBV, HCV and HIV-1, respectively. The analytical sensitivity of the DPX test determined by the German Red Cross Blood Donor Service was 0·6 and 3·8 IU/ml for HAV and B19.

Conclusion: These multiplex and multi-dye blood screening assays represent a flexible NAT screening system for mini-pools between 6 and 96 samples per pool and fulfil all requirements of the European Pharmacopoeia for HCV and B19V testing of plasma for fractionation. The inclusion of a new multi-dye technology means discriminatory assays are no longer required for either test thus improving workflow, turn-around time and minimize the risk of obtaining a reactive result for which the virus cannot be identified.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1423-0410.2012.01635.xDOI Listing

Publication Analysis

Top Keywords

analytical sensitivity
16
german red
12
red cross
12
cross blood
12
blood donor
12
donor service
12
multi-dye nucleic
8
nucleic acid
8
acid amplification
8
amplification technology
8

Similar Publications

Background: Butaro Cancer Center of Excellence (BCCOE) was founded to serve Rwanda's rural low-income population, providing subsidized cancer diagnosis and treatment with transport stipends for the lowest-income patients. We examined whether travel distance to BCCOE was associated with advanced-stage diagnoses and treatment completion.

Methods: We conducted a retrospective cohort study using medical record data from BCCOE patients with pathologically-confirmed breast cancer from 2012-2016.

View Article and Find Full Text PDF

Ways to Measure Metals: From ICP-MS to XRF.

Curr Environ Health Rep

January 2025

School of Health Sciences, Purdue University, West-Lafayette, IN, 47906, USA.

Purpose Of Review: This review explores the use of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and X-ray Fluorescence (XRF) for quantifying metals and metalloids in biological matrices such as hair, nails, blood, bone, and tissue. It provides a comprehensive overview of these methodologies, detailing their technological limitations, application scopes, and practical considerations for selection in both laboratory and field settings. By examining traditional and novel aspects of each method, this review aims to guide researchers and clinical practitioners in choosing the most suitable analytical tool based on their specific needs for sensitivity, precision, speed, and sample preparation.

View Article and Find Full Text PDF

The BioSentinel CubeSat was deployed on the Artemis-I mission in November 2022 and has been continuously transmitting physical measurements of the space radiation environment since that time. Just before mission launch, we published computational model predictions of the galactic cosmic ray exposure expected inside BioSentinel for multiple locations and configurations. The predictions utilized models for the ambient galactic cosmic ray environment, radiation physics and transport, and BioSentinel geometry.

View Article and Find Full Text PDF

Objective: Fetal cerebellar abnormalities are associated with neurodevelopmental disorders and structural brain malformations. Accurate and early diagnosis is crucial for prenatal counseling and planning postnatal interventions. While prenatal ultrasound is a key tool for detecting fetal brain abnormalities, variations in diagnostic accuracy across studies necessitate a systematic evaluation of its effectiveness in diagnosing cerebellar abnormalities.

View Article and Find Full Text PDF

Facile synthesis of hierarchically flower-like hollow covalent organic frameworks for enrichment and metabolic analysis of benzophenone derivatives in mouse serum.

J Chromatogr A

January 2025

Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China. Electronic address:

Benzophenone derivatives (BPs), as synthetic chemicals widely used in personal care products, have drawn increasing attention due to their potential health risks. However, monitoring BPs in biological samples remains challenging due to their complex matrices and the deficiency in sensitivity and selectivity in current methods. Herein, a method combining hierarchically flower-like hollow covalent organic frameworks (HFH-COFs) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the enrichment and detection of BPs in serum samples.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!