Background: The cobas TaqScreen MPX Test, version 2.0, a multiplex, multi-dye nucleic acid amplification technology (NAT) test from Roche was evaluated by two European Blood Banks, the German Red Cross Blood Donor Service, Frankfurt, Germany and Centro de Hemoterapia y Hemodonación de Castilla y León, Valladolid, Spain. In addition, the cobas TaqScreen DPX Test was evaluated for the simultaneous detection and quantitation of parvovirus B19 and the detection of hepatitis A virus (HAV).
Study Design And Methods: The performances of the two tests were evaluated regarding the analytical sensitivity, the reproducibility of the tests using samples containing low concentrations of each virus and cross-contamination using samples containing high titres of virus.
Results: The analytical sensitivity of the MPX Test, version 2.0, obtained by the German Red Cross Blood Donor Service was 1·1, 3·9 and 43·3 IU/ml for HBV, HCV and HIV-1, respectively. The comparable analytical sensitivity at Centro de Hemoterapia y Hemodonación de Castilla y León was 3·5, 17·6 and 50·6 IU/ml for HBV, HCV and HIV-1, respectively. The analytical sensitivity of the DPX test determined by the German Red Cross Blood Donor Service was 0·6 and 3·8 IU/ml for HAV and B19.
Conclusion: These multiplex and multi-dye blood screening assays represent a flexible NAT screening system for mini-pools between 6 and 96 samples per pool and fulfil all requirements of the European Pharmacopoeia for HCV and B19V testing of plasma for fractionation. The inclusion of a new multi-dye technology means discriminatory assays are no longer required for either test thus improving workflow, turn-around time and minimize the risk of obtaining a reactive result for which the virus cannot be identified.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1423-0410.2012.01635.x | DOI Listing |
BMC Cancer
January 2025
Brigham and Women's Hospital, 75 Francis Street, Boston, MA, 02115, USA.
Background: Butaro Cancer Center of Excellence (BCCOE) was founded to serve Rwanda's rural low-income population, providing subsidized cancer diagnosis and treatment with transport stipends for the lowest-income patients. We examined whether travel distance to BCCOE was associated with advanced-stage diagnoses and treatment completion.
Methods: We conducted a retrospective cohort study using medical record data from BCCOE patients with pathologically-confirmed breast cancer from 2012-2016.
Curr Environ Health Rep
January 2025
School of Health Sciences, Purdue University, West-Lafayette, IN, 47906, USA.
Purpose Of Review: This review explores the use of Inductively Coupled Plasma Mass Spectrometry (ICP-MS) and X-ray Fluorescence (XRF) for quantifying metals and metalloids in biological matrices such as hair, nails, blood, bone, and tissue. It provides a comprehensive overview of these methodologies, detailing their technological limitations, application scopes, and practical considerations for selection in both laboratory and field settings. By examining traditional and novel aspects of each method, this review aims to guide researchers and clinical practitioners in choosing the most suitable analytical tool based on their specific needs for sensitivity, precision, speed, and sample preparation.
View Article and Find Full Text PDFLife Sci Space Res (Amst)
February 2025
NASA Ames Research Center, Moffett Field, CA 94035, United States.
The BioSentinel CubeSat was deployed on the Artemis-I mission in November 2022 and has been continuously transmitting physical measurements of the space radiation environment since that time. Just before mission launch, we published computational model predictions of the galactic cosmic ray exposure expected inside BioSentinel for multiple locations and configurations. The predictions utilized models for the ambient galactic cosmic ray environment, radiation physics and transport, and BioSentinel geometry.
View Article and Find Full Text PDFJ Matern Fetal Neonatal Med
December 2025
Department of Ultrasound, The Second Affiliated Hospital of Fujian Medical University, Quanzhou, China.
Objective: Fetal cerebellar abnormalities are associated with neurodevelopmental disorders and structural brain malformations. Accurate and early diagnosis is crucial for prenatal counseling and planning postnatal interventions. While prenatal ultrasound is a key tool for detecting fetal brain abnormalities, variations in diagnostic accuracy across studies necessitate a systematic evaluation of its effectiveness in diagnosing cerebellar abnormalities.
View Article and Find Full Text PDFJ Chromatogr A
January 2025
Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China. Electronic address:
Benzophenone derivatives (BPs), as synthetic chemicals widely used in personal care products, have drawn increasing attention due to their potential health risks. However, monitoring BPs in biological samples remains challenging due to their complex matrices and the deficiency in sensitivity and selectivity in current methods. Herein, a method combining hierarchically flower-like hollow covalent organic frameworks (HFH-COFs) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the enrichment and detection of BPs in serum samples.