Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The aim of this study was to assess the effectiveness of cardiac resynchronization therapy (CRT) by intracardiac delay optimization using echocardiography. Sixty-five patients were implanted with a CRT device randomly assigned to receive simultaneous biventricular pacing or echo-optimized sequential CRT. Forty-two patients were defined as responders and 23 patients were classified as non-responders. During a 12-month follow-up period, the positive response rate, QRS duration, New York Heart Association class, mitral insufficiency grade, left ventricular end-systolic volume and LV end-diastolic volume were similar in the optimized and non-optimized groups (P>0.05), whereas 6-minute walking distance, quality-of-life score, left ventricular (LV) ejection fraction and aortic velocity time integral were significantly improved in the optimized group (P<0.05). The baseline QRS durations of the responders and non-responders were similar (P>0.05), whereas heart failure aetiology, clinical and echocardiographic measurements showed significant differences (P<0.05). The mean decrease in QRS duration after 12 months of CRT used for separating responders and non-responders was significantly different (P<0.05), and significant differences were observed in the mean decrease of QRS duration between responders and non-responders (P<0.05). Echocardiographic optimization may further improve the effectiveness of CRT. Moreover, severe mitral regurgitation and greater LV volume are likely to indicate a poor response to CRT.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3524119 | PMC |
http://dx.doi.org/10.3892/etm.2012.802 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!