Objectives: To determine the safety, clinical yield, and cost of computed tomography angiography (CTA) use in the workup of potential renal transplant recipients.

Design: Single-site, retrospective review of medical, surgical, and radiologic records.

Setting: Large university tertiary care center.

Patients: Potential recipients of transplants from living donors.

Interventions: Computed tomography with and without 100 mL of iodixanol intravenous contrast enhancement as part of the preoperative workup.

Main Outcome Measures: Mean pre- and post-CTA estimated glomerular filtration rate and number of patients requiring emergent dialysis after CTA, number of patients who had their treatment changed by CTA findings, patient predictors of significant CTAs, and cost per significant CTA.

Results: From July 20, 2006, through December 10, 2010, a total of 179 transplant candidates underwent CTA. Forty-two patients were predialysis at the time of CTA. Mean (SD) serum creatinine levels in this group were unchanged after CTA (5.06 [2.13] mg/dL vs 5.00 [2.28] mg/dL [to convert to micromoles per liter, multiply by 88.4], P = .49), and no patients required subsequent emergent dialysis. Forty-one patients (22.9%) had their treatment changed by CTA findings. Multivariate logistic regression analysis revealed 3 patient history and physical criteria that predicted significant CTA findings: chronic infection (odds ratio, 10.91; 95% CI, 2.72-43.69; P < .001), patient weight less than 69 kg (3.11; 1.49-6.51; P < .001), and ventral torso surgical scarring (4.13; 1.57-10.84; P < .001). Diagnostic cost per significant CTA study was $2660, with an estimated reduced cost of $1480 per significant study with screening using 1 of the 3 predictors.

Conclusion: Diagnostic CTA is a safe and cost-effective procedure for both operative planning and screening for potentially prohibitive abdominal disease.

Download full-text PDF

Source
http://dx.doi.org/10.1001/archsurg.2012.1466DOI Listing

Publication Analysis

Top Keywords

computed tomography
12
cta findings
12
cta
10
potential renal
8
renal transplant
8
tomography angiography
8
number patients
8
emergent dialysis
8
treatment changed
8
changed cta
8

Similar Publications

Objectives: Due to the increasing use of cone-beam computed tomography (CBCT) in dentistry and considering the effects of radiation on radiosensitive organs, the aim of this study was to investigate the effect of shielding on absorbed dose of eyes, thyroid and breasts in scans conducted with different parameters using two different fields of view (FOV).

Methods: Dose measurements were calculated on a tissue-equivalent female phantom by repeating each scanning parameter three times and placing at least two thermoluminescent dosimeters (TLD) on each organ, with the averages then taken. The same CBCT scans were performed in two different FOV with shielding including thyroid collar, radiation safety glasses and lead apron and without shielding.

View Article and Find Full Text PDF

Purpose: Pulmonary perfusion imaging is a key lung health indicator with clinical utility as a diagnostic and treatment planning tool. However, current nuclear medicine modalities face challenges like low spatial resolution and long acquisition times which limit clinical utility to non-emergency settings and often placing extra financial burden on the patient. This study introduces a novel deep learning approach to predict perfusion imaging from non-contrast inhale and exhale computed tomography scans (IE-CT).

View Article and Find Full Text PDF

Background: Accurate differentiation between benign and malignant pancreatic lesions is critical for effective patient management. This study aimed to develop and validate a novel deep learning network using baseline computed tomography (CT) images to predict the classification of pancreatic lesions.

Methods: This retrospective study included 864 patients (422 men, 442 women) with confirmed histopathological results across three medical centers, forming a training cohort, internal testing cohort, and external validation cohort.

View Article and Find Full Text PDF

Background: This study aimed to evaluate the effects of 4-hexylresorcinol (4HR), a synthetic compound with antioxidant and stress-modulating properties, on diabetic sarcopenia in the masseter muscle.

Methods: A controlled, parallel-arm study was conducted using 38 Sprague-Dawley rats divided into diabetic and non-diabetic groups. Diabetes was induced with streptozotocin (STZ), and the groups were further subdivided to receive weekly subcutaneous injections of either 4HR or saline.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!