Background: Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis.
Methods: We studied 2 groups, each consisting of 10 healthy subjects, at 1.5 T or 3T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (Ell(RV) and Ell(LV)) and LV long-axis radial strain (Err(LAX)) were derived from the 4-chamber cine, and LV short-axis circumferential and radial strains (Ecc(SAX), Err(SAX)) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups.
Results: In all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p>0.05). In general Ecc(SAX) was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5 T (CV 13.3% and 46% global and segmental respectively) and 3T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was Ell(RV) (CV 1.5 T 28.7% and 53.2%; 3T 43.5% and 63.3% global and segmental respectively).
Conclusions: CMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5 T and 3T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR-FT can be fully established in clinical routine for quantitative assessment of wall mechanics and strain.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ejrad.2012.11.012 | DOI Listing |
J Cytol
November 2024
Department of Pathology, Mardin Training and Research Hospital, Mardin, Turkey.
Background: The Bethesda System for Reporting Thyroid Cytology (TBSRTC) recommended for the interpretation of needle aspiration cytology of the thyroid, is the most widely used worldwide. Studies have shown that the disagreement between observers, especially in the Bethesda III and IV diagnostic categories, is not insignificant at 10%-40%. In the TBSRTC 2023 version, some definitions were removed and simplified, and molecular pathology was proposed as a complement to cytopathology.
View Article and Find Full Text PDFBMC Oral Health
December 2024
Department of Oral Surgery, Universidad de Salamanca, Salamanca, 37007, Spain.
Background: Knowing the available dental space in a patient is crucial for orthodontists to develop a good treatment plan.
Objectives: To compare and evaluate the reliability, reproducibility, and accuracy of three measurement methods on models: conventional, mobile app, and digital software.
Materials And Methods: Maxillary and mandibular dental plaster models of 20 subjects with permanent dentition were analyzed.
Front Cardiovasc Med
December 2024
Department of Ultrasonography, Shenzhen Children's Hospital, Shenzhen, China.
Background: Percutaneous extracorporeal membrane oxygenation (ECMO) is administered to pediatric patients with cardiogenic shock or cardiac arrest. The traditional method uses focal echocardiography to complete the left ventricular measurement. However, echocardiographic determination of the ejection fraction (EF) by manual tracing of the endocardial borders is time consuming and operator dependent.
View Article and Find Full Text PDFBMC Musculoskelet Disord
December 2024
Department of Foot and Ankle Surgery, Beijing Jishuitan Hospital, Capital Medical University, No.31, Xinjiekou East Street, Xicheng District, Beijing, 100035, China.
Background: Hallux valgus (HV) is a multiplanar deformity and surgical treatment is often guided by two-dimensional radiographic parameters. This study assessed the reliability and accuracy of the AIR classification(The first metatarsal head's lateral edge can be delineated as angular (type A), round (type R), or intermediate (type I) through visual inspection or circle measurements on weight-bearing radiographs.)commonly used in clinical settings to categorize the shape of the lateral edge of the first metatarsal head, against measurements from weight-bearing computed tomography (WBCT).
View Article and Find Full Text PDFAm J Ophthalmol
December 2024
Bascom Palmer Eye Institute, University of Miami, Miami, FL, USA. Electronic address:
Purpose: Primarily, to evaluate the repeatability and reproducibility of the new non-contact esthesiometer (NCE) in healthy subjects. Secondarily, the corneal sensitivity threshold measurements of the NCE were compared with those of the Cochet-Bonnet esthesiometer (CBE).
Design: Assessment reliability study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!