Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This paper focuses on implementing a design space approach and on the critical process parameters (CPPs) to consider when applying the Quality by Design (QbD) concepts outlined in ICH Q8(R2), Q9 and Q10 to analytical method development and optimization for three chiral compounds developed as modulators of small conductance calcium-activated potassium (SK) channels. In this sense, an HPLC method using a polysaccharide-based stationary phase containing a cellulose tris (4-chloro-3-methylphenylcarbamate) chiral selector in polar organic solvent chromatography mode was considered. The effects of trifluoroacetic acid (TFA) and n-hexane concentration in an acetonitrile (MeCN) mobile phase were investigated under a wide range of column temperatures. Good correlations were found between the observed data obtained after using a central composite design and the expected chromatographic behaviours predicted by applying the design of experiments-design space (DoE-DS) methodology. The critical quality attribute represented here by the separation criterion (S(crit)) allowed assessing the quality of the enantioseparation. Baseline separation for the compounds of interest in an analysis time of less than 20 min was possible due to the original and powerful tools applied which facilitated an enhanced method comprehension. Finally, the advantage of the DoE-DS approach resides in granting the possibility to concurrently assess robustness and identify the optimal conditions which are compound dependent.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jpba.2012.10.015 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!