A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Mixed-signal template-based reduction scheme for stimulus artifact removal in electrical stimulation. | LitMetric

Simultaneous electrical stimulation and recording are used to gain insights into the function of neuronal circuitry. However, artifacts produced by the electrical stimulation pulses prevent the recording of neural responses during, and a short period after, the stimulation duration. In this work, we describe a mixed-signal recording topology with template subtraction for removing the artifact during the stimulation pulse. Emulated artifacts generated from a lumped electrical circuit model and experimental artifacts in cardiac cell cultures are used to evaluate the topology. The simulations show that delays between the emulated artifact and its estimated compensation template represent the largest error source of the analog template subtraction. The quantization error appears like random noise and determines the threshold level for the action potential detection. Simulations show that removal of the artifacts is possible, allowing the detection of action potentials during the stimulation pulsing period, even for high-amplitude saturating artifacts. Measurement results with artifacts elicited in cardiac cell cultures show feasible applications of this topology. The proposed topology therefore promisingly opens up a previously unavailable detection window for improving the analysis of the neuronal activity.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-012-1013-6DOI Listing

Publication Analysis

Top Keywords

electrical stimulation
12
template subtraction
8
cardiac cell
8
cell cultures
8
stimulation
6
artifacts
6
mixed-signal template-based
4
template-based reduction
4
reduction scheme
4
scheme stimulus
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!