Introduction: Venous anastomosis is one of the most challenging technical aspects of microsurgery. Recently, it has been expedited by the use of an anastomotic coupler device in multiple reconstructive venues. However, there are few studies in the literature evaluating the use of the coupler in lower extremity reconstruction. We present one of the largest series to date examining the use of the venous coupler in microsurgical reconstruction of the lower extremity.

Methods: A retrospective chart review was completed including all lower extremity soft tissue reconstruction over a 26-month period performed by the senior authors. The Synovis venous coupler was used in all coupled venous anastomoses (Synovis Micro Companies Alliance Inc, Birmingham, Alabama). Patients under 18 years of age were excluded.

Results: Forty-nine free flaps were performed in 48 patients. All arterial anastomoses were hand sewn. The anastomotic venous coupler was used in 48 of 49 flaps (97.9%) with 1 hand-sewn case due to attending preference during early experience. There were no intraoperative vascular complications. Successful free flap reconstruction occurred in 47 of 49 flaps (95.9%). Of the flap losses, one was due to delayed venous thrombosis, the other attributed to delayed arterial thrombosis. Venous thrombosis rate was 2.1% when the coupler was used (1 failure in 48 flaps).

Conclusions: The use of the venous coupler device in lower extremity reconstruction can be performed with a high degree of success. The potential of the venous coupler for reduced operative time, more efficient anastomoses with decreased ischemia, and reduced thrombotic rates represents potential benefits of this important tool.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SAP.0b013e31825c07a1DOI Listing

Publication Analysis

Top Keywords

venous coupler
24
lower extremity
16
coupler device
12
venous
10
coupler
9
free flap
8
anastomotic venous
8
extremity reconstruction
8
venous thrombosis
8
lower
5

Similar Publications

[Mechanical vascular anastomoses].

Oper Orthop Traumatol

December 2024

Plastisch- und Handchirurgische Klinik, Universitätsklinik Erlangen, Krankenhausstr. 12, 91054, Erlangen, Deutschland.

Background: Mechanical anastomoses of blood vessels represent a major advance in modern surgery. Highly specialized instruments ensure the precise connection of blood vessels, enabling the immediate restoration of blood flow. Ring coupler systems for venous anastomoses, in particular, have proven themselves in clinical practice due to their convenience and reliability and are now an indispensable part of surgical routines.

View Article and Find Full Text PDF

A novel arterial coupler with non-return snap-fit connection approach optimized arterial end-to-end anastomotic technique: An experimental study.

Chin J Traumatol

September 2024

Department of Vascular and Endovascular Surgery, Changzheng Hospital, Naval Medical University, Shanghai, 200003, China. Electronic address:

Purpose: Hand-sewn anastomosis as the gold standard of vascular anastomosis cannot fully meet the requirements of vascular anastomosis in speed and quality. Various vascular couplers have been developed to ameliorate this situation. Most of them are mainly used for venous anastomosis rather than arterial anastomosis, even though it is generally acknowledged that in almost all operations involving vascular reconstruction, it is the arteries that need to be anastomosed faster and more accurately and not the veins.

View Article and Find Full Text PDF

Key Clinical Message: Topical papaverine is an effective vasodilator that can be used for dilating small veins to accept venous couplers for thumb replantation. This technique corrects size mismatches for successful venous anastomosis and minimizes postoperative complications.

Abstract: Thumb replantation is a complex microsurgical procedure used to restore function and appearance after amputation.

View Article and Find Full Text PDF

Introduction: Effective vascular anastomosis is crucial for successful hand surgery, particularly in traumatic injuries where rapid restoration of blood flow is essential. The Synovis microvascular anastomotic coupler system presents a novel approach by potentially offering faster and more reliable outcomes than traditional suturing methods. This study was conducted to assess the effectiveness and safety of the Synovis coupler for microvascular anastomoses in the wrist, evaluating anastomosis time, patency rates, and complication rates.

View Article and Find Full Text PDF

Background This study aimed to identify outcome predictors with the GEM microvascular coupler system (GEM Coupler) in a series of patients undergoing free flap reconstruction for head and neck defects. Methodology In this retrospective chart review of 218 consecutive microvascular procedures performed on 204 patients at an academic tertiary care center, demographics, comorbidities, surgical data, and outcomes were retrieved. The endpoints for the analysis were microvascular revision surgery and flap survival.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!