A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of temporal artery, nasopharyngeal, and axillary temperature measurement during anesthesia in children. | LitMetric

Study Objective: To evaluate the accuracy and precision of a new, noninvasive infrared thermometer applied to the temporal artery.

Design: Prospective randomized study.

Setting: Trakya University Hospital.

Patients: 60 ASA physical status 1 and 2 children undergoing surgery.

Interventions: During anesthesia, temperature measurements were recorded with three different techniques: temporal artery, nasopharynx, and axillary temperature.

Measurements: Temperatures measured from the nasopharynx, temporal artery, and the axilla were recorded at 15-minute intervals for the first hour, then at 30-minute intervals until the completion of surgery. During each measurement, heart rate and midarterial pressure were recorded.

Main Results: There were no statistically significant differences between temperatures recorded at the temporal artery and nasopharynx at 15, 30, 45, 60, 90, and 120 minutes, and the completion of surgery. Axillary temperatures were statistically lower than those recorded at the nasopharynx and the temporal artery (P < 0.001). Bland-Altman plots showed a correlation of temperature measurements between the temporal artery and nasopharyngeal methods. The axillary method had a lower correlation with the temporal artery and the nasopharyngeal methods.

Conclusions: The temporal artery thermometer is a substitute for the nasopharyngeal thermometer for core temperature measurement during anesthesia in children.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jclinane.2012.05.003DOI Listing

Publication Analysis

Top Keywords

temporal artery
32
artery nasopharyngeal
12
artery
8
temperature measurement
8
measurement anesthesia
8
anesthesia children
8
temporal
8
temperature measurements
8
artery nasopharynx
8
nasopharynx temporal
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!