Coherent speckle influences the resulting image when narrow spectral line-width and single spatial mode illumination are used, though these are the same light-source properties that provide the best radiance-to-cost ratio. However, a suitable size of the detection pinhole can be chosen to maintain adequate optical sectioning while making the probability density of the speckle noise more normal and reducing its effect. The result is a qualitatively better image with improved contrast, which is easier to read. With theoretical statistics and experimental results, we show that the detection pinhole size is a fundamental parameter for designing imaging systems for use in turbid media.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3412991PMC
http://dx.doi.org/10.1117/1.JBO.17.8.085001DOI Listing

Publication Analysis

Top Keywords

detection pinhole
12
speckle noise
8
adequate optical
8
optical sectioning
8
optimal detection
4
pinhole lowering
4
lowering speckle
4
noise maintaining
4
maintaining adequate
4
sectioning confocal
4

Similar Publications

Spectrally encoded flow cytometry using few-mode fiber collection.

Biomed Opt Express

January 2025

Faculty of Biomedical Engineering, Technion-Israel Institute of Technology, Haifa 3200003, Israel.

In fiber-based confocal microscopy, using two separate fibers for illumination and collection enables the use of a few-mode fiber to achieve an effect similar to opening the pinhole in a conventional confocal microscope. In some Fourier-domain applications, however, or when a spectral measurement is involved, the coherent light detection would lead to noticeable spectral modulation artifacts that result from differential mode delay, an effect caused by the multimode propagation in the collection fiber. After eliminating these artifacts by using mode-dependent polarization control, we demonstrate effective spectrally encoded imaging with improved signal efficiency and lower speckle noise, and only a minor, negligible reduction in lateral and axial resolutions.

View Article and Find Full Text PDF

Impact on Distance and Near Contrast Sensitivity of Multifocal Contact Lenses: A Systematic Review.

Eye Contact Lens

November 2024

Department of Optics, Pharmacology and Anatomy (K.J.M.-G., D.F., D.P.P.), University of Alicante, Alicante, Spain; and Advanced Clinic Optometry Unit (D.P.P.), Department of Ophthalmology, Medimar International Hospital, Alicante, Spain.

Purpose: To investigate the impact on distance and near contrast sensitivity (CS) after fitting multifocal contact lenses (MFCLs) for presbyopia correction according to the scientific evidence already published.

Methods: Three bibliographic search was conducted on PubMed, Web of Sciences, and Scopus. Inclusion criteria were articles written in English evaluating distance and/or near CS in presbyopic patients using MFCLs, controlled clinical trials, and articles published from 2000 to 2024.

View Article and Find Full Text PDF

Purpose: We are developing a three-dimensional X-ray fluorescence computed tomography (3D XFCT) system using non-radioactive-labeled compounds for preclinical studies as a new modality that provides images of biological functions. Improvements in image quality and detection limits are required for the in vivo imaging. The aim of this study was to improve the quality of XFCT images by applying a deep image prior (DIP), which is a type of convolutional neural network, to projection images as a pre-denoising method, and then compare with DIP post-denoising.

View Article and Find Full Text PDF

Background: Human immunodeficiency virus (HIV) is a lentivirus. It is transmitted through sexual intercourse, shared intravenous drugs, contaminated needle use, blood transfusion, and mother-to-child transmission. Of the patients with HIV, 50%-75% have ocular manifestations and this may be the primary presentation.

View Article and Find Full Text PDF

Cutting tools with orderly arranged diamond grits using additive manufacturing show better sharpness and longer service life than traditional diamond tools. A retractable needle jig with vacuum negative pressure was used to absorb and place grits in an orderly arranged manner. However, needle hole wear after a long service time could not promise complete grit adsorption forever.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!