Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The platelet transcriptome has been extensively characterised using distinct genetic profiling platforms, with evolving evidence for differential expression patterns between healthy individuals and subject cohorts with various haematologic and cardiovascular disorders. Traditional technological platforms for platelet genetic biomarker quantification have limited applicability for clinical molecular diagnostics due to inherent complexities related to RNA isolation and analysis. We have previously established the feasibility of fluorescent microspheres as a simple and reproducible strategy for simultaneous quantification of platelet mRNAs from small volume of blood using intact platelets. We now extend these observations by formally comparing in a 50-member normal cohort the cross-platform behaviour of fluorescent microspheres to the currently accepted Q-PCR standard, using a clinically relevant 15-biomarker gene subset able to discriminate among normal and thrombocytosis cohorts. When compared to Q-PCR, genetic biomarker quantification using fluorescent microspheres demonstrated lower coefficients of variation for low-abundant transcripts, better linearity in serially diluted samples, and good overall between-platform consistency via the geometric mean regression. Neither platform demonstrated age or gender effects for any of the 15 biomarkers studied. Binding site saturation for highly abundant transcripts using fluorescent microspheres can be readily eliminated using an optimal platelet number corresponding to 0.3 ml of peripheral blood, additionally applicable to thrombocytopenic cohorts. These data provide a detailed cross-platform analysis using a relevant biomarker subset, further highlighting the applicability of fluorescent microspheres as potentially superior to Q-PCR for platelet mRNA diagnostics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1160/TH12-04-0257 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!