Automatic trajectory planner for StereoElectroEncephaloGraphy procedures: a retrospective study.

IEEE Trans Biomed Eng

Dipartimento di Elettronica, Informatica e Bioingegneria, Politecnico di Milano, Milan 20133, Italy.

Published: April 2013

In StereoElectroEncephaloGraphy (SEEG) procedures, intracerebral electrodes are implanted in order to identify the epileptogenic zone in drug-resistant epileptic patients. This paper presents an automatic multitrajectory planner that computes the best trajectory in terms of distance from vessels and guiding screws angle, once the candidate entry and target regions are quickly and roughly defined. The planning process is designed also to spare some brain structures, such as cella media and trigone of the lateral ventricles and brain stem. The planner was retrospectively evaluated on 15 patients who had previously undergone SEEG investigation. Quantitative comparison was performed computing for each patient and for each electrode trajectory 1) the Euclidean distance from the closest vessel; 2) the trajectory incidence angle (guiding screws angle); and 3) the sulcality value. The automatic planner proved to satisfy the clinical requirements, planning safe trajectories in a clinical-compatible timeframe. Qualitative evaluation performed by three neurosurgeons showed that the automatically computed trajectories would have been accepted by them.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TBME.2012.2231681DOI Listing

Publication Analysis

Top Keywords

guiding screws
8
screws angle
8
automatic trajectory
4
planner
4
trajectory planner
4
planner stereoelectroencephalography
4
stereoelectroencephalography procedures
4
procedures retrospective
4
retrospective study
4
study stereoelectroencephalography
4

Similar Publications

In a slim-floor structural system, beams and slabs are placed at the same level, reducing the overall floor height and material usage in vertical structures, thereby improving economic efficiency. The use of slim-floor structures is common practice in Finnish construction where these structures are typically constructed using hollow-concrete slabs and welded steel box beams. However, in Finland, only a few buildings utilise cross-laminated timber (CLT) slabs in slim-floor structures, and none have incorporated the composite action between CLT and steel beams.

View Article and Find Full Text PDF

Background: Hemodynamically unstable pelvic ring fractures from high-energy trauma are critical injuries in trauma care, requiring urgent intervention and precise diagnostics. With ongoing advancements in trauma management, treatment strategies have evolved, with some techniques becoming obsolete as new ones emerge. This study aimed to evaluate changes and trends in treatment algorithms for these injuries over approximately 40 years.

View Article and Find Full Text PDF

Objective: To maximize local tumor control, stabilize affected bones, and preserve or replace joints with minimal interventional burden, thereby enhancing quality of life for empowered living.

Indications: Suitable for patients with bone metastases, particularly those with severe pain and/or fractures and appropriate life expectancy.

Contraindications: In primary bone tumors, refer to the sarcoma surgery team for evaluation of wide resection.

View Article and Find Full Text PDF

Minimally Invasive Placement of Cannulated Headless Compression Screws for Reduction of Sacroiliac Luxation in 14 Cats.

Vet Comp Orthop Traumatol

December 2024

Surgery Department, Evidensia Dierenziekenhuis Hart van Brabant, Waalwijk, Brabant, The Netherlands.

Objective:  To describe percutaneous fluoroscopy-guided placement of self-drilling, self-tapping, 3.0 mm cannulated headless compression screws (HCS) for surgical reduction of sacroiliac luxation (SIL) in cats, and to document clinical outcome.

Materials And Methods:  Medical records of cats with SIL, managed by percutaneous fluoroscopy-guided placement of a 3.

View Article and Find Full Text PDF

Mandibular molar distalization is a complex orthodontic movement due to anatomic and biomechanical limitations. The opportunity to use a custom-made appliance with skeletal anchorage should be an advantageous alternative to traditional solutions: multiple extractions, interproximal reductions, vestibular inclination of incisal group. : A 14-year-old female patient with Class II malocclusion and ectopic upper and lower canines was treated in the lower arch with a custom-made appliance anchored on a mini-screw in the right buccal-shelf where the ectopy and crowding was severe.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!