A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 143

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A PHP Error was encountered

Severity: Warning

Message: Attempt to read property "Count" on bool

Filename: helpers/my_audit_helper.php

Line Number: 3100

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler

File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Broadband high-frequency measurement of ultrasonic attenuation of tissues and liquids. | LitMetric

Broadband high-frequency measurement of ultrasonic attenuation of tissues and liquids.

IEEE Trans Ultrason Ferroelectr Freq Control

Christian Doppler Laboratory of Photoacoustic Imaging and Laser Ultrasonics, Linz, Austria.

Published: December 2012

AI Article Synopsis

  • The study focuses on measuring the acoustic attenuation of biomaterials for ultrasonic imaging, emphasizing the need for improved techniques as frequency ranges expand.
  • A novel method was developed using short laser pulses and piezoelectric transducers to generate and detect ultrasound, with the laser method showing significantly higher signal amplitude and bandwidth.
  • The method was successfully applied to measure attenuation in porcine fat and liquids like human blood and olive oil, yielding results consistent with existing literature.

Article Abstract

The ongoing expansion of the frequency range used for ultrasonic imaging requires increasing attention to the acoustic attenuation of biomaterials. This work presents a novel method for measuring the attenuation of tissue and liquids in vitro on the basis of single transmission measurements. Ultrasound was generated by short laser pulses directed onto a silicon wafer. In addition, unfocused piezoelectric transducers with a center frequency of 50 MHz were used to detect and emit ultrasound. The laser ultrasound method produces signals with a peak frequency of 30 MHz. In comparison to piezoelectric generation, pulse laser excitation provides approximately 4 times higher amplitudes and 20% larger bandwidth. By using two excitation methods in succession, the attenuation parameters of porcine fat samples with thicknesses in the range of 1.5 to 20 mm could be determined quantitatively within a total frequency range of 5 to 45 MHz. The setup for liquid measurements was tested on samples of human blood and olive oil. Our results are in good agreement with reports in literature.

Download full-text PDF

Source
http://dx.doi.org/10.1109/TUFFC.2012.2504DOI Listing

Publication Analysis

Top Keywords

frequency range
8
frequency mhz
8
broadband high-frequency
4
high-frequency measurement
4
measurement ultrasonic
4
attenuation
4
ultrasonic attenuation
4
attenuation tissues
4
tissues liquids
4
liquids ongoing
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!