A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flanged-edge transverse gradient coil design for a hybrid LINAC-MRI system. | LitMetric

Flanged-edge transverse gradient coil design for a hybrid LINAC-MRI system.

J Magn Reson

School of Information Technology and Electrical Engineering, The University of Queensland, Brisbane, QLD 4072, Australia.

Published: January 2013

MRI can be combined with other systems, such as linear accelerators (LINACs) to provide image-guided therapy. However, in some configurations this requires splitting the MRI scanner to provide a central gap large enough to ensure dual access for the accelerator and the patient. This raises technical difficulties for maintaining a high gradient coil performance. In this research, a dedicated split transverse gradient coil was designed with a flange connected to the central coil end, which provided an additional surface for the current to flow. The coil was compared to existing designs, in terms of coil performance and eddy current effects. It was found that a flanged-edge coil design produced a better coil performance and more moderate eddy currents than those of the other designs. It is hoped that this study will help to inform the design of optimal gradient coils for split MRI systems with a large central gap.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2012.11.017DOI Listing

Publication Analysis

Top Keywords

gradient coil
12
coil performance
12
transverse gradient
8
coil
8
coil design
8
central gap
8
flanged-edge transverse
4
gradient
4
design hybrid
4
hybrid linac-mri
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!