Objective: To assess the accuracy of cone-beam computed tomography (CBCT) in periimplant fenestration and dehiscence detection, and to determine the effects of 2 voxel sizes and scan modes.
Study Design: One hundred titanium implants were placed in bovine ribs in which periimplant fenestration and dehiscence were simulated. CBCT images were acquired with the use of 3 protocols of the i-CAT NG unit: A) 0.2 mm voxel size half-scan (180°); B) 0.2 mm voxel size full-scan (360°); and C) 0.12 mm voxel size full scan (360°). Receiver operating characteristic curves and diagnostic values were obtained. The Az values were compared with the use of analysis of variance.
Results: The Az value for dehiscence in protocol A was significantly lower than those of B or C (P < .01). They did not statistically differ for fenestration (P > .05).
Conclusions: Protocol B yielded the highest values. The voxel sizes did not affect fenestration and dehiscence detection, and for dehiscence full-scan performed better than half-scan.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.oooo.2012.10.003 | DOI Listing |
BMC Oral Health
November 2024
Department of Orthodontics (WangFuJing Campus), School of Stomatology, Capital Medical University, Scylla alley No.11, Beijing, 100006, P. R. China.
Clin Oral Investig
November 2024
Faculty of Dentistry, Dentomaxillofacial Radiology Department, Nevşehir Hacı Bektaş Veli University, Nevşehir, Turkey.
Objectives: This study sought to assess the diagnostic value of ultrasonography (USG) and cone-beam computed tomography (CBCT) for the visibility of periodontal defects.
Materials And Methods: We created 37 periodontal defects (dehiscence and fenestration) in fresh sheep mandibles. Two dentomaxillofacial radiologists assessed the CBCT and ultrasonographic images for the presence of defects.
Front Neurol
October 2024
Department of Head and Neck Surgery & Communication Sciences, Rutgers Robert Wood Johnson Medical School, New Brunswick, NJ, United States.
Background: Superior semicircular canal dehiscence (SSCD) is a vestibular-cochlear disorder in humans in which a pathological third mobile window of the otic capsule creates changes to the flow of sound pressure energy through the perilymph/endolymph. The primary symptoms include sound-induced dizziness/vertigo, inner ear conductive hearing loss, autophony, headaches, and visual problems. We have developed an animal model of this human condition in the Mongolian Gerbil that uses surgically created SSCD to induce the condition.
View Article and Find Full Text PDFAcad Radiol
October 2023
Department of Periodontics and Oral Medicine, School of Dentistry, University of Michigan, Ann Arbor, Michigan, USA (A.R.B., H.-L.C.).
Rationale And Objectives: This study aims to (1) describe a periodontal and implant ultrasound imaging phantom designed for training of common periodontal and peri-implant soft- and hard-tissue deficiencies, and (2) detail the specific anatomical phantom features and showcase imaging data obtained from intraoral scans, cone beam computed tomography (CBCT) as well as ultrasound.