External noise control in inherently stochastic biological systems.

J Math Phys

Department of Mathematics, University of California, Irvine, California 92697, USA ; Center for Complex Biological Systems, University of California, Irvine, California 92697, USA ; Center for Mathematical and Computational Biology, University of California, Irvine, California 92697, USA.

Published: November 2012

Biological systems are often subject to external noise from signal stimuli and environmental perturbations, as well as noises in the intracellular signal transduction pathway. Can different stochastic fluctuations interact to give rise to new emerging behaviors? How can a system reduce noise effects while still being capable of detecting changes in the input signal? Here, we study analytically and computationally the role of nonlinear feedback systems in controlling external noise with the presence of large internal noise. In addition to noise attenuation, we analyze derivatives of Fano factor to study systems' capability of differentiating signal inputs. We find effects of internal noise and external noise may be separated in one slow positive feedback loop system; in particular, the slow loop can decrease external noise and increase robustness of signaling with respect to fluctuations in rate constants, while maintaining the signal output specific to the input. For two feedback loops, we demonstrate that the influence of external noise mainly depends on how the fast loop responds to fluctuations in the input and the slow loop plays a limited role in determining the signal precision. Furthermore, in a dual loop system of one positive feedback and one negative feedback, a slower positive feedback always leads to better noise attenuation; in contrast, a slower negative feedback may not be more beneficial. Our results reveal interesting stochastic effects for systems containing both extrinsic and intrinsic noises, suggesting novel noise filtering strategies in inherently stochastic systems.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3505197PMC
http://dx.doi.org/10.1063/1.4762825DOI Listing

Publication Analysis

Top Keywords

external noise
24
positive feedback
12
noise
11
inherently stochastic
8
biological systems
8
internal noise
8
noise attenuation
8
loop system
8
slow loop
8
negative feedback
8

Similar Publications

Soft and stretchable strain sensors are crucial for applications in human-machine interfaces, flexible robotics, and electronic skin. Among these, capacitive strain sensors are widely used and studied; however, they face challenges due to material and structural constraints, such as low baseline capacitance and susceptibility to external interference, which result in low signal-to-noise ratios and poor stability. To address these issues, we propose a U-shaped electrode flexible strain sensor based on liquid metal elastomer (LME).

View Article and Find Full Text PDF

A parallelized field-programmable gate array (FPGA) architecture is proposed to realize an ultra-fast, compact, and low-cost dual-channel ultra-wideband (UWB) pulsed-radar system. This approach resolves the main shortcoming of current FPGA-based radars, namely their low processing throughput, which leads to a significant loss of data provided by the radar receiver. The architecture is integrated with an in-house UWB pulsed radar operating at a sampling rate of 20 gigasamples per second (GSa/s).

View Article and Find Full Text PDF

Background Light Suppression for Multispectral Imaging in Surgical Settings.

Sensors (Basel)

December 2024

Institute of Smart Systems and Services, Pforzheim University, 75175 Pforzheim, Germany.

Multispectral imaging (MSI) enables non-invasive tissue differentiation based on spectral characteristics and has shown great potential as a tool for surgical guidance. However, adapting MSI to open surgeries is challenging. Systems that rely on light sources present in the operating room experience limitations due to frequent lighting changes, which distort the spectral data and require countermeasures such as disruptive recalibrations.

View Article and Find Full Text PDF

Fracto-emission is the ejection of electrons and positive ions from matter undergoing a mechanical fracture. The creation and propagation of fractures in insulating material can generate an electrical signal that can be detected using a sufficiently fast signal recorder. The theoretical equations related to crack creation/propagation that induce an externally electric signal are detailed for two conditions: with and without an external applied electric voltage.

View Article and Find Full Text PDF

Robustly detecting mpox and non-mpox using a deep learning framework based on image inpainting.

Sci Rep

January 2025

School of Mathematics and Systems Science, Guangdong Polytechnic Normal University, No. 293, Zhongshan Avenue West, Tianhe District, Guangzhou, 510665, China.

Due to the lack of efficient mpox diagnostic technology, mpox cases continue to increase. Recently, the great potential of deep learning models in detecting mpox and non-mpox has been proven. However, existing methods are susceptible to interference from various noises in real-world settings, require diverse non-mpox images, and fail to detect abnormal input, which makes them unsuitable for practical deployment and application.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!