We previously described loop-mediated isothermal amplification (LAMP) for detection of Schistosoma haematobium and S. mansoni DNA in infected snails. In the present study, we adapted the LAMP assay for application in field laboratories in schistosomiasis-endemic areas. Isolation of DNA was simplified by blotting snail tissue (extracted in NaOH/sodium dodecyl sulfate) onto treated membranes, which enabled preservation at ambient temperatures. A ready-mix of LAMP reagents, suitable for shipment at ambient temperature and storage in minimal refrigeration, was used. Local survey teams without experience in molecular biology acquired operational expertise with this test within a few hours. Fifty-four field-caught snails were tested locally by LAMP and 59 were tested at similar conditions in Jerusalem. The LAMP results were consistent with those of a polymerase chain reaction; only four samples showed false-negative results. Results indicate that LAMP assays are suitable for detection of S. haematobium and S. mansoni in low-technology parasitology laboratories in which schistosomiasis elimination activities are undertaken.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3583328PMC
http://dx.doi.org/10.4269/ajtmh.2012.12-0208DOI Listing

Publication Analysis

Top Keywords

loop-mediated isothermal
8
isothermal amplification
8
field laboratories
8
haematobium mansoni
8
lamp
6
evaluation loop-mediated
4
amplification suitable
4
suitable molecular
4
molecular monitoring
4
monitoring schistosome-infected
4

Similar Publications

The genus comprises fungal species closely related to , with and being medically important. These species can cause infections in both immunocompetent and immunocompromised individuals. The current detection methods are limited, prompting the need for rapid and specific diagnostic tools.

View Article and Find Full Text PDF

Diagnostics often require specialized equipment and trained personnel in laboratory settings, creating a growing need for point-of-care tests (POCTs). Among the genetic testing methods available, Loop-mediated Isothermal Amplification (LAMP) offers a viable solution for developing genetic POCT due to its compatibility with simplified devices. This study aimed to create a genetic test that integrates all steps from sample processing to analyzing results while minimizing the complexity, handling, equipment, and time required.

View Article and Find Full Text PDF

Epidemic infections and spreading antibiotic resistance require diagnostic tests that can be rapidly adopted. To reduce the usually time-consuming adaptation of molecular diagnostic tests to changing targets, we propose the novel approach of a repurposable sensing electrode functionalization with a universal, target-independent oligonucleotide probe. In the liquid phase covering the electrode, the target sequence is amplified by MD LAMP (mediator-displacement loop-mediated isothermal amplification) releasing a generic methylene blue-labeled mediator, which specifically hybridizes to the solid-phase probe.

View Article and Find Full Text PDF

Isothermal nucleic acid amplification for monitoring hand-foot-and-mouth disease: current status and future implications.

Mikrochim Acta

December 2024

School of Public Health, the key Laboratory of Environmental Pollution Monitoring and Disease Control, Ministry of Education, Guizhou Medical University, Guiyang, 561113, China.

With the global prevalence of the hand-foot-and-mouth disease (HFMD) epidemic, the development of reliable point-of-care testing (POCT) is crucial for the timely identification and prevention of outbreaks. Isothermal nucleic acid amplification techniques (INAATs) have attracted much attention because of their high efficiency for rapid diagnosis. In this work, we systematically summarize the current status of INAATs for HFMD and discuss advantages and drawbacks of various INAATs for HFMD.

View Article and Find Full Text PDF

This report presents a patient with pneumonia (LP), initially presented with fever and mild hypoxemia, with subsequent progression to severe pneumonia during hospitalization. Despite multiple negative urinary antigen tests using Ribotest , the diagnosis was confirmed via the loop-mediated isothermal amplification method of lower respiratory tract secretions. This case highlights the diagnostic limitations of Ribotest and emphasizes the importance of a comprehensive diagnostic strategy, incorporating nucleic acid amplification tests or culture in suspected patients with LP.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!