Background: Robotic-assisted unicompartmental knee arthroplasty (UKA) with rigid bone fixation "can significantly improve implant placement and leg alignment. The aim of this cadaveric study was to determine whether the use of robotic systems with dynamic bone tracking would provide more accurate UKA implant positioning compared to the conventional manual technique.

Methods: Three-dimensional CT-based preoperative plans were created to determine the desired position and orientation for the tibial and femoral components. For each pair of cadaver knees, UKA was performed using traditional instrumentation on the left side and using a haptic robotic system on the right side. Postoperative CT scans were obtained and 3D-to-3D iterative closest point registration was performed. Implant position and orientation were compared to the preoperative plan.

Results: Surgical RMS errors for femoral component placement were within 1.9 mm and 3.7° in all directions of the planned implant position for the robotic group, while RMS errors for the manual group were within 5.4mm and 10.2°. Average RMS errors for tibial component placement were within 1.4mm and 5.0° in all directions for the robotic group; while, for the manual group, RMS errors were within 5.7 mm and 19.2°.

Conclusions: UKA was more precise using a semiactive robotic system with dynamic bone tracking technology compared to the manual technique.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.knee.2012.11.001DOI Listing

Publication Analysis

Top Keywords

rms errors
16
unicompartmental knee
8
knee arthroplasty
8
dynamic bone
8
bone tracking
8
position orientation
8
robotic system
8
implant position
8
component placement
8
robotic group
8

Similar Publications

This paper is devoted to the development of a window-type inductive current transformer (iCT) with a rated primary current equal to 400 A and two secondary windings with rated currents of 5 A and 1 A. Its novelty concerns the presentation of this process in the case of an iCT with a 0.2S accuracy class ensured not only for a sinusoidal current of a frequency of 50 Hz but also for the transformation of distorted current in the harmonic frequency range from 50 Hz to 5 kHz.

View Article and Find Full Text PDF

Single-cell RNA sequencing (scRNA-seq) has advanced our understanding of cell types and their heterogeneity within the human liver, but the spatial organization at single-cell resolution has not yet been described. Here we apply multiplexed error robust fluorescent in situ hybridization (MERFISH) to map the zonal distribution of hepatocytes, spatially resolve subsets of macrophage and mesenchymal populations, and investigate the relationship between hepatocyte ploidy and gene expression within the healthy human liver. Integrating spatial information from MERFISH with the more complete transcriptome produced by single-nucleus RNA sequencing (snRNA-seq), also reveals zonally enriched receptor-ligand interactions.

View Article and Find Full Text PDF

Background: This study aims to evaluate the impact of different thresholds and voxel sizes on the accuracy of Cone-beam computed tomography (CBCT) tooth reconstruction and to assess the accuracy of fused CBCT and intraoral scanning (IOS) tooth models using curvature continuity algorithms under varying thresholds and voxel conditions.

Methods: Thirty-two isolated teeth were digitized using IOS and CBCT at two voxel sizes and five threshold settings. Crown-root fusion was performed using a curvature continuity algorithm.

View Article and Find Full Text PDF

The effect of right versus left long-term single-sided deafness on sound source localization.

J Otol

July 2024

Department of Otolaryngology Head and Neck Surgery, Chinese PLA General Hospital, Chinese PLA Medical School, Beijing, 100853, China.

Purpose: To analyze the effect of right versus left long-term single-sided deafness (SSD) on sound source localization (SSL), discuss the necessity of intervention and treatment for SSD patients, and analyze the therapeutic effect of long-term unilateral cochlear implantation (UCI) from the perspective of SSL.

Methods: This study included 25 patients with SSD, 11 patients with UCI, and 30 participants with normal hearing (NH). Their SSL ability was tested by obtaining their average root mean square (RMS) error values of SSL test.

View Article and Find Full Text PDF

Audiological performance and subjective satisfaction of the ADHEAR system in experienced pediatric users with unilateral microtia and aural atresia.

Int J Pediatr Otorhinolaryngol

December 2024

Division of Otology, Department of Otorhinolaryngology & Head and Neck Surgery, Linkou Chang Gung Memorial Hospital, Taoyuan, Taiwan; School of Medicine, Chang Gung University, Taoyuan, Taiwan. Electronic address:

Introduction: Despite the reported auditory deficits and developmental challenges in children with unilateral microtia and aural atresia (UMAA), there remains a lack of consensus on early intervention with bone conduction hearing aids (BCHAs) to restore binaural hearing due to the uncertain clinical benefits and intolerability of the conventional devices. Previous studies investigating the auditory benefits under binaural hearing condition were limited and demonstrated controversial opinions in heterogenous patient groups with various devices. Our study aimed to evaluate the audiological performance, including monoaural and binaural hearing, and subjective satisfaction of the ADHEAR system, a novel adhesive BCHA, in experienced pediatric users with UMAA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!