Introduction: Campylobacter is an important causative agent of intestinal infections in humans. Bacteremia is detected in less than 1% of patients, mainly in immunocompromised patients and in extreme age groups. Cellulitis is a relatively common manifestation of Campylobacter infection, but concomitant bacteremia is a rare event. Infections of the pacemaker area are caused primarily by staphylococci, followed by fungi, streptococci and Gram-negative rods. To the best of our knowledge, this is the first case report of pacemaker pocket infection and bacteremia caused by Campylobacter fetus.

Case Presentation: A 72-year-old Croatian Caucasian man with myelodysplasia, impaired fasting glucose levels and a recently implanted permanent pacemaker was admitted to hospital after six days of fever, development of red swelling of the pacemaker pocket area and worsening of his general condition. No antibiotic therapy was introduced in the outpatient setting. He denied any recent gastrointestinal disturbances. With the exception of an elevated leukocyte count, erythrocyte sedimentation rate, and C-reactive protein and blood glucose levels, other laboratory findings were normal. Treatment with vancomycin plus netilmicin was introduced, and a surgical incision with drainage of the pacemaker pocket was performed. The entire pacemaker system was removed and a new one re-implanted after 14 days of antibiotic therapy. Transesophageal echocardiography showed no pathological findings. Three subsequent blood cultures obtained on admission as well as swab culture of the incised pacemaker area revealed Campylobacter fetus; stool and pacemaker lead cultures were negative. According to the microbiological results, antibiotic therapy was changed to ciprofloxacin plus netilmicin. A clinical examination and the results of a laboratory analysis performed after two weeks of therapy were within normal limits.

Conclusion: Myelodysplasia, impaired fasting glucose levels and older age could be contributing factors for the development of bacteremic Campylobacter fetus cellulitis. Emergent surgical and antibiotic treatment are mandatory and provide the optimal outcome for such types of pacemaker pocket infection.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3520688PMC
http://dx.doi.org/10.1186/1752-1947-6-414DOI Listing

Publication Analysis

Top Keywords

pacemaker pocket
16
campylobacter fetus
12
glucose levels
12
antibiotic therapy
12
pacemaker
10
case report
8
pacemaker area
8
pocket infection
8
myelodysplasia impaired
8
impaired fasting
8

Similar Publications

Background: Guideline-recommended strategies to interrupt chronic anticoagulation with warfarin or direct oral anticoagulants (DOAC) during the perioperative period of cardiac implantable electronic device (CIED) surgery differ worldwide. There is uncertainty concerning the benefits and harms of interrupted and uninterrupted anticoagulation in patients undergoing CIED surgery.

Objectives: To assess the benefits and harms of interrupted anticoagulation (IAC) with either warfarin or DOAC in the perioperative period of CIED surgery versus uninterrupted anticoagulation (UAC), with or without heparin bridging, during an equivalent time frame, for CIED surgery.

View Article and Find Full Text PDF

Pocket hematoma is a common and serious complication following cardiac implantable electronic device (CIED) implantation, contributing to significant morbidity and mortality. This study aimed to evaluate the efficacy of a novel pocket compression device in reducing pocket hematoma occurrence. We enrolled 242 patients undergoing CIED implantation, randomly assigning them to receive either the novel compression vest with a pressure cuff or conventional sandbag compression.

View Article and Find Full Text PDF

Purpose: Pacemaker-related infections are serious complications of cardiac implantable electronic devices (CIEDs). This case report aims to describe the occurrence of pacemaker pocket infection and recurrent ventricular tachycardia (VT) in a Chinese amateur violinist with sick sinus syndrome (SSS), and to explore the possible connection between occupational habits and the infection, as well as VT.

Methods: A 76-year-old male violinist with a Biotronik Evia DR dual-chamber pacemaker presented with syncope and signs of a pacemaker pocket infection three years after implantation.

View Article and Find Full Text PDF

Background: Removal of cardiac implantable electronic devices (CIEDs) is strongly recommended for CIED-related infections, and leadless pacemakers (LPs) are increasingly used for reimplantation. However, the optimal timing and safety of LP implantation after CIED removal for infection remains unclear.This systematic review and meta-analysis aimed to assess complication rates (all-cause mortality and reinfection) when LP implantation was performed simultaneously with or after CIED removal.

View Article and Find Full Text PDF

Background: Transvenous lead extraction (TLE) has become an essential component of lead management strategies, but it carries the risk of severe complications, including damage to the tricuspid valve. Currently, there are no established predictors that can help prevent these complications.

Case Summary: An 84-year-old male with a dual-chamber pacemaker was admitted to the hospital due to a pocket fistula resulting from a local infection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!