Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Design: Retrospective study comparing cranial facet joint violation rates of open and percutaneous pedicle screws inserted using 3-dimensional image-guidance.
Objective: To determine the rate of cranial facet joint violation in intraoperative computed tomography (CT) image-guided lumbar pedicle screw instrumentation and compare facet joint violation rates between CT image-guided open and percutaneous techniques.
Summary Of Background Data: Facet joint violation by pedicle screws can potentially result in a higher rate of adjacent segment degeneration. Reported cranial facet joint violation rates range from 7% to 100%. Intraoperative image-guidance, which has enhanced pedicle screw placement accuracy, may aid in avoiding impingement of the cranial facet joints.
Methods: We reviewed 188 cases of 3-dimensional image-guided lumbar pedicle screw instrumentation from November 2006 to December 2011. The cranial screws of each construct were graded by 3 reviewers according to the Seo classification (0 = no impingement; 1 = screw head in contact/suspected to be in contact with joint; 2 = screw clearly invaded the joint) on intraoperative axial CT images. If there was a difference in evaluation, a consensus was reached to arrive at a single grade. The χ2 test was used to determine significance between the open and percutaneous group (α = 0.05).
Results: A total of 370 screws (245 open, 125 percutaneous) were graded. Overall facet joint violation rate was 18.9% (grade 1 = 16.2%, grade 2 = 2.7%). Open technique (grade 1 = 22.4%, grade 2 = 4.1%) had a significantly higher violation rate than percutaneous technique (grade 1 = 4%, grade 2 = 0%) (P < 0.0001). There is a trend of an increasing likelihood of facet joint violation from L1 to L5.
Conclusion: The use of intraoperative CT image-guidance in lumbar pedicle screw placement resulted in a facet joint violation rate at the lower end of the reported range in literature. The percutaneous technique has a significantly lower facet violation rate than the open technique.
Level Of Evidence: 4.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BRS.0b013e31827ecbf1 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!