A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of cranial facet joint violation rates between open and percutaneous pedicle screw placement using intraoperative 3-D CT (O-arm) computer navigation. | LitMetric

Study Design: Retrospective study comparing cranial facet joint violation rates of open and percutaneous pedicle screws inserted using 3-dimensional image-guidance.

Objective: To determine the rate of cranial facet joint violation in intraoperative computed tomography (CT) image-guided lumbar pedicle screw instrumentation and compare facet joint violation rates between CT image-guided open and percutaneous techniques.

Summary Of Background Data: Facet joint violation by pedicle screws can potentially result in a higher rate of adjacent segment degeneration. Reported cranial facet joint violation rates range from 7% to 100%. Intraoperative image-guidance, which has enhanced pedicle screw placement accuracy, may aid in avoiding impingement of the cranial facet joints.

Methods: We reviewed 188 cases of 3-dimensional image-guided lumbar pedicle screw instrumentation from November 2006 to December 2011. The cranial screws of each construct were graded by 3 reviewers according to the Seo classification (0 = no impingement; 1 = screw head in contact/suspected to be in contact with joint; 2 = screw clearly invaded the joint) on intraoperative axial CT images. If there was a difference in evaluation, a consensus was reached to arrive at a single grade. The χ2 test was used to determine significance between the open and percutaneous group (α = 0.05).

Results: A total of 370 screws (245 open, 125 percutaneous) were graded. Overall facet joint violation rate was 18.9% (grade 1 = 16.2%, grade 2 = 2.7%). Open technique (grade 1 = 22.4%, grade 2 = 4.1%) had a significantly higher violation rate than percutaneous technique (grade 1 = 4%, grade 2 = 0%) (P < 0.0001). There is a trend of an increasing likelihood of facet joint violation from L1 to L5.

Conclusion: The use of intraoperative CT image-guidance in lumbar pedicle screw placement resulted in a facet joint violation rate at the lower end of the reported range in literature. The percutaneous technique has a significantly lower facet violation rate than the open technique.

Level Of Evidence: 4.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e31827ecbf1DOI Listing

Publication Analysis

Top Keywords

facet joint
36
joint violation
36
cranial facet
20
pedicle screw
20
violation rates
16
open percutaneous
16
violation rate
16
screw placement
12
lumbar pedicle
12
facet
11

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!