Background: The long-term management of stroke is an area of increasing clinical interest, and it is important to identify therapeutic interventions that are effective in the chronic phase post stroke.

Objective: To conduct a systematic review on the effectiveness of functional electrical stimulation (FES) in improving lower extremity function in chronic stroke.

Methods: Multiple databases (PubMed, CINAHL, EMBASE, and Scopus) were searched for relevant articles. Studies were included for review if (1) ≥50% of the study population has sustained a stroke, (2) the study design was a randomized controlled trial (RCT), (3) the mean time since stroke was ≥6 months, (4) FES or neuromuscular electrical stimulation (NMES) was compared to other interventions or a control group, and (5) functional lower extremity outcomes were assessed. Methodological quality was assessed using the PEDro tool. A standardized mean difference (SMD ± SE and 95% confidence interval [CI]) was calculated for the 6-minute walk test (6MWT). Pooled analysis was conducted for treatment effect of FES on the 6MWT distance using a fixed effects model.

Results: Seven RCTs (PEDro scores 5-7) including a pooled sample size of 231 participants met inclusion criteria. Pooled analysis revealed a small but significant treatment effect of FES (0.379 ± 0.152; 95% CI, 0.081 to 0.677; P = .013) on 6MWT distance.

Conclusion: FES may be an effective intervention in the chronic phase post stroke. However, its therapeutic value in improving lower extremity function and superiority over other gait training approaches remains unclear.

Download full-text PDF

Source
http://dx.doi.org/10.1310/tsr1906-491DOI Listing

Publication Analysis

Top Keywords

electrical stimulation
12
lower extremity
12
functional electrical
8
chronic phase
8
phase post
8
improving lower
8
extremity function
8
pooled analysis
8
treatment fes
8
stroke
5

Similar Publications

System-level wearable electronics require to be flexible to ensure conformal contact with the skin, but they also need to integrate rigid and bulky functional components to achieve system-level functionality. As one of integration methods, folding integration offers simplified processing and enhanced functionality through rigid-soft region separation, but so far, it has mainly been applied to modality of electrical sensing and stimulation. This paper introduces a vialess heterogeneous skin patch with multi modalities that separates the soft region and strain-robust region through folded structure.

View Article and Find Full Text PDF

Cross-Species Characterization of Transcranial Ultrasound Propagation.

Brain Stimul

January 2025

Pazhou Lab (Guangzhou), Guangzhou 510335, China; The School of Automation Science and Engineering, South China University of Technology, Guangzhou 510641, China. Electronic address:

Background: Transcranial ultrasound stimulation (TUS) has shown promising prospects as a non-invasive neuromodulation technique for both animals and humans. However, ultrasonic propagation characteristics within the brain differ significantly from those in free space. There is currently a lack of comprehensive studies on the effects of skull thickness on focal point position, full width at half maximum (FWHM), and acoustic intensity.

View Article and Find Full Text PDF

The journey of bone repair is a lengthy process. Traditionally, oral or topical medications have been employed to facilitate healing, approaches that are not only costly but may also lead to adverse effects such as gastrointestinal damage. With advancements in electrophysiology, the significance of bioelectric activity in tissue repair has become increasingly prominent, thereby enhancing the focus on research into electroacupuncture (EA) for bone repair.

View Article and Find Full Text PDF

Spiking neural networks seek to emulate biological computation through interconnected artificial neuron and synapse devices. Spintronic neurons can leverage magnetization physics to mimic biological neuron functions, such as integration tied to magnetic domain wall (DW) propagation in a patterned nanotrack and firing tied to the resistance change of a magnetic tunnel junction (MTJ), captured in the domain wall-magnetic tunnel junction (DW-MTJ) device. Leaking, relaxation of a neuron when it is not under stimulation, is also predicted to be implemented based on DW drift as a DW relaxes to a low energy position, but it has not been well explored or demonstrated in device prototypes.

View Article and Find Full Text PDF

Multimodal imaging of murine cerebrovascular dynamics induced by transcranial pulse stimulation.

Alzheimers Dement

January 2025

Institute for Biomedical Engineering and Institute of Pharmacology and Toxicology, Faculty of Medicine, University of Zurich, Zurich, Switzerland.

Introduction: Transcranial pulse stimulation (TPS) is increasingly being investigated as a promising potential treatment for Alzheimer's disease (AD). Although the safety and preliminary clinical efficacy of TPS short pulses have been supported by neuropsychological scores in treated AD patients, its fundamental mechanisms are uncharted.

Methods: Herein, we used a multi-modal preclinical imaging platform combining real-time volumetric optoacoustic tomography, contrast-enhanced magnetic resonance imaging, and ex vivo immunofluorescence to comprehensively analyze structural and hemodynamic effects induced by TPS.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!