A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Improving the Presage® polymer radiosensitivity for hot cell and glovebox 3D characterization. | LitMetric

RadBall is a novel, passive, radiation detection device that provides 3D mapping of radiation from areas where measurements have not been possible previously due to lack of access or extremely high radiation doses. This kind of technology is beneficial when decommissioning and decontamination of nuclear facilities occur. The key components of the RadBall technology include a tungsten outer shell that houses a radiosensitive PRESAGE polymer. The 1.0-cm-thick tungsten shell has a number of holes that allow photons to reach the polymer, thus generating radiation tracks that are analyzed to characterize the radiation sources within the contaminated area being considered. Facilities being mapped frequently have to be shut down to minimize radiation exposures to workers; therefore, reducing the mapping or characterization time is significant. The objective of this study was to reduce the RadBall deployment time by increasing the radiosensitivity of the PRESAGE formulation. The new formulation is four times more radiosensitive than the original formulation. Consequently, RadBall deployment times can be reduced fourfold, which is a considerable improvement.

Download full-text PDF

Source
http://dx.doi.org/10.1097/HP.0b013e3182632926DOI Listing

Publication Analysis

Top Keywords

radball deployment
8
radiation
6
improving presage®
4
presage® polymer
4
polymer radiosensitivity
4
radiosensitivity hot
4
hot cell
4
cell glovebox
4
glovebox characterization
4
radball
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!