Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Hemodialysis techniques for small animals have not been established because no small dialysis apparatus has been available. We recently developed a small-size dialyzer and established an appropriate blood purification system for small animals. To confirm the appropriate dialysate flow rate, bovine blood was dialyzed for 60 min at a fixed blood flow rate of 1.0 mL/min and variable dialysate flow rates. Blood urea nitrogen and creatinine levels decreased significantly at a dialysate flow rate of 5 mL/min (from 13.7 ± 0.2 to 10.3 ± 1.2 mg/dL and 1.07 ± 0.15 to 0.61 ± 0.12 mg/dL, respectively, P < 0.05). To determine the appropriate in vivo conditions, extracorporeal circulation was performed in anesthetized male Sprague-Dawley rats at a dialysate flow rate of 0.0 mL/min, for 240 min, and at variable blood flow rates. Extracorporeal circulation was successful at a blood flow rate of 1.0 mL/min, but not 1.5 mL/min. To establish in vivo hemodialysis conditions, we used the animal model of end stage renal failure. Sprague-Dawley rats were fed a 0.75% adenine-containing diet for 3 weeks, after which they received hemodialysis for 120 min at a dialysate and blood flow rate of 5.0 and 1.0 mL/min, respectively. There were no significant changes in systolic blood pressure or heart rate during dialysis. Thus, this blood purification system can be safely used for small animals at a dialysate flow rate of 5.0 mL/min and a blood flow rate of 1.0 mL/min. This system provides a basis for further research on hemodialysis therapy.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1744-9987.2012.01091.x | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!