A tunable, coherence-free, high-resolution microwave photonic bandpass filter, which is compatible to be inserted in a conventional fiber optic link, is presented. It is based on using two cross gain modulation based wavelength converters in a recursive loop. The double cross gain modulation technique solves the semiconductor optical amplifier facet reflection problem in the conventional recursive structure; hence the new microwave photonic signal processor has no coherent interference and no phase-induced intensity noise. It allows arbitrary narrow-linewidth telecommunication-type lasers to be used while enabling stable filter operation to be realized. The filter passband frequency can be tuned by using a wavelength tunable laser and a wavelength dependent time delay component. Experimental results demonstrate robust high-resolution bandpass filter operation with narrow-linewidth sources, no phase-induced intensity noise and a high signal-to-noise ratio performance. Tunable coherence-free operation of the high-resolution bandpass filter is also demonstrated.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.20.022987DOI Listing

Publication Analysis

Top Keywords

bandpass filter
16
tunable coherence-free
12
microwave photonic
12
cross gain
12
gain modulation
12
photonic bandpass
8
double cross
8
modulation technique
8
phase-induced intensity
8
intensity noise
8

Similar Publications

The Value of P-Wave Parameters Changes in Predicting Catheter Ablation Outcomes for Paroxysmal Atrial Fibrillation.

Ann Noninvasive Electrocardiol

January 2025

Department of Cardiology, University Hospitals of Leicester NHS Trust, Glenfield Hospital, Leicester, UK.

Background: Pulmonary vein isolation (PVI) is the most promising management method for paroxysmal atrial fibrillation (PAF). The P wave in the electrocardiogram (ECG) represents atrial depolarization. This study aims to correlate P-wave parameters after PVI with outcomes.

View Article and Find Full Text PDF

Background: Mice play a crucial role in studying the mechanisms of general anesthesia. However, identifying reliable EEG markers for different depths of anesthesia induced by multifarious agents remains a significant challenge. Spindle activity, typically observed during NREM sleep, reflects synchronized thalamocortical activity and is characterized by a frequency range of 7-15 Hz and a duration of 0.

View Article and Find Full Text PDF

This study introduces a high-performance 4-channel Metal-Insulator-Metal (MIM) diplexer, employing silver and Teflon, optimized for advanced photonic applications. The proposed diplexer, configured with two novel band-pass filters (BPFs), operates across four distinct wavelength bands (843 nm, 1090 nm, 1452 nm, 1675 nm) by precisely manipulating the passband dimensions. Utilizing Finite-Difference Time-Domain (FDTD) simulations, the designed diplexer achieves exceptional sensitivity values of 3500 nm/RIU, 4250 nm/RIU, 3375 nm/RIU, and 4003 nm/RIU, along with high figures of merit (FOM) ranging from 113.

View Article and Find Full Text PDF

Patients With .

J Neurotrauma

December 2024

Department of Medical Sciences, Section of Neurosurgery, Uppsala University, Uppsala, Sweden.

This study compared the roles of extraparenchymal autonomic nervous system (ANS) control of cerebral blood flow (CBF) versus intraparenchymal cerebrovascular autoregulation in 487 patients with aneurysmal subarachnoid hemorrhage (SAH) and 413 patients with traumatic brain injury (TBI). Vasomotion intensity of extraparenchymal and intraparenchymal vessels were quantified as the amplitude of oscillations of arterial blood pressure (ABP) and intracranial pressure (ICP) in the very low frequency range of 0.02-0.

View Article and Find Full Text PDF

This study investigates human semicircular canal (SCC) dynamics under off-center rotational conditions. Previous research has modeled human rotational perception and the dynamic response of the SCCs by assuming a centered rotation state, where the rotation axis aligns with the SCC's center. However, this assumption is not representative of most real-life rotational situations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!