Objective: This study aimed to evaluate the difficult intravenous access (DIVA) score, a clinical prediction rule, which states that children with a score of 4 or more will have a 50% higher rate of a failed intravenous placement on the first attempt compared with the mean failure rate.

Methods: This was a prospective cohort study in children 0 to 14 years, undergoing peripheral intravenous placement by doctors in the emergency department of a medium-sized general hospital. Before intravenous placement attempts, demographic data inclusive of age and DIVA score were recorded. A maximum of 3 attempts per doctor were allowed, after which a more senior doctor undertook subsequent attempts. The site of successful placement was recorded.

Results: Five hundred children were enrolled. The male-female ratio was 1.3:1. One hundred thirty-three (26.6%) were less than 1 year, 103 (20.6%) were aged 1 to 2 years, and 264 (52.8%) were 3 years or older. One hundred ten children (22%) had a failed intravenous placement on the first attempt. Of the 151 children with a DIVA score of 4 or more, 57 (37.7%) had a failed intravenous placement, validating the clinical prediction rule. Only 5 subjects (1%) did not have intravenous placement after 6 attempts.

Conclusions: This study validates DIVA score and provides a simple tool that can enhance the accuracy of the information offered to parents as it relates to the success rates of intravenous placement in children.

Download full-text PDF

Source
http://dx.doi.org/10.1097/PEC.0b013e3182768bc9DOI Listing

Publication Analysis

Top Keywords

intravenous placement
28
diva score
16
clinical prediction
12
prediction rule
12
failed intravenous
12
intravenous
9
difficult intravenous
8
intravenous access
8
placement
8
placement attempt
8

Similar Publications

Rationale: We report the efficacy of combination prednisolone and intravenous (IV) rituximab as an immunosuppressive regimen for a young male presenting with extensive venous thromboembolism including a submassive pulmonary embolism secondary to life-threatening nephrotic syndrome from very high risk anti-phospholipase-A2 receptor (PLA2R) positive membranous nephropathy. Initial treatment was with mechanical thrombectomy and anticoagulation. Thereafter, oral prednisolone was initiated to induce remission, during a period of uninterrupted anticoagulation.

View Article and Find Full Text PDF

Efficacy of a vein visualisation device for facilitating peripheral venous line placement in adult patients with sickle cell disease: A randomised clinical trial.

Int J Nurs Stud

December 2024

Service de Médecine Interne, Centre National de Référence des Syndromes Drépanocytaires Majeurs de l'Adulte, AP-HP, Hôpital Européen Georges Pompidou, Assistance Publique-Hôpitaux de Paris, 20 rue Leblanc, F-75908 Paris cedex 15, France; Service d'aval des urgences, hopital Henri-Mondor Assistance Publique-Hôpitaux de Paris, 1 rue Gustave Eiffeil, 94000 Créteil, France; Université Paris Cité, Paris, France. Electronic address:

Background: Intravenous (IV) access is often required for the treatment of vaso-occlusive crises in patients with sickle cell disease, but can be particularly challenging due to recurrent venous damage. The AccuVein® device, uses near-infrared light technology to visualise veins for easier venepuncture.

Methods: A randomised, controlled trial of the efficacy of the AccuVeinAV400® device in the replacement of peripheral venous lines during a vaso-occlusive crisis was conducted at two centres in France.

View Article and Find Full Text PDF

Background/aims: Functional lumen imaging probe (FLIP) Panometry has demonstrated utility in the assessment of esophageal motility as a complement to existing methodologies like high-resolution manometry. However, as FLIP is typically performed with sedation during routine endoscopy, there is potential for impact of sedation agents on esophageal motility. We aim to examine the effects of conscious sedation with midazolam and fentanyl on FLIP Panometry metrics and classification.

View Article and Find Full Text PDF

: Complications, namely, catheter-related thrombosis (CRT) and venous stenosis, are associated with non-cuffed hemodialysis catheters used for emergency vascular access. However, only a few reports have demonstrated changes in the venous lumen and intravenous thrombosis after catheter removal. In this study, we comprehensively investigated the risk factors for residual thrombus 1 month after hemodialysis catheter removal.

View Article and Find Full Text PDF

is a rapidly emerging fungal pathogen associated with high resistance rates, particularly in healthcare settings. It most commonly affects patients with severe underlying medical conditions and requiring complex medical care. Patients with invasive medical devices tend to be at increased risk for getting and developing infection.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!