We have theoretically and experimentally investigated using a dual parallel Mach-Zehnder modulator (DP-MZM) in an RF photonic link to cancel the second harmonic distortion due to the photodiode. Biasing the DP-MZM for single sideband modulation, the second harmonic generated by the DP-MZM can be set out of phase with the second harmonic generated at the photodiode. We measure the output intercept point of the second harmonic distortion of the link to be 55.3 dBm, which is an improvement of over 32 dB as compared to only the photodiode.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.20.027163DOI Listing

Publication Analysis

Top Keywords

second harmonic
20
harmonic distortion
12
dual parallel
8
parallel mach-zehnder
8
harmonic generated
8
second
5
harmonic
5
cancellation photodiode-induced
4
photodiode-induced second
4
distortion single
4

Similar Publications

Finding novel efficient nonlinear optical materials with large second-order nonlinearity for the UV spectral range remains a formidable challenge, especially for silicate systems. Using a high-temperature solid reaction in a tight vacuum environment, two ultraviolet nonlinear optical materials with a moderate second harmonic generation (SHG) response have been created: PbSiOC and PbCaSiO. The SHG values they computed are roughly 2.

View Article and Find Full Text PDF

Background: While Alzheimer Disease (AD) patients' difficulty to recognize face identity (Werheid & Clare, 2007) has been mainly attributed to episodic and semantic memory impairments, these patients can also show abnormal difficulties at matching of unfamiliar faces for their identity, suggesting impaired perceptual function (Lavallée et al., 2016). However, since this latter evidence is based on explicit behavioural measures, the difficulties of AD patients can be due to many factors (e.

View Article and Find Full Text PDF

Organic-inorganic hybrid lead halides have been extensively studied due to their outstanding physical properties and diverse compositional elements. However, environmentally benign tin-based hybrids with remarkable flexibility in bandgap engineering have been less investigated. Herein, we report the successful design and synthesis of three tin-based organic-inorganic hybrid compounds through precise molecular modification: [Me(i-Pr)N][SnBr] (), [MeCHCl(i-Pr)N][SnBr] (), and [MeCHBr(i-Pr-Br)N][SnBr] ().

View Article and Find Full Text PDF

Symmetry Breaking in Twisted Mixed-Dimensional Heterostructure Interfaces for Multifunctional Polarization-Sensitive Photodetection.

ACS Nano

January 2025

Center for High Pressure Science (CHiPS), State Key Laboratory of Metastable Materials Science & Technology, Yanshan University, Qinhuangdao 066004, China.

Moiré superlattices, created by stacking different van der Waals materials at twist angles, have emerged as a versatile platform for exploring intriguing phenomena such as topological properties, superconductivity, the quantum anomalous Hall effect, and the unconventional Stark effect. Additionally, the formation of moiré superlattice potential can generate spontaneous symmetry breaking, leading to an anisotropic optical response and electronic transport behavior. Herein, we propose a two-step chemical vapor deposition (CVD) strategy for synthesizing WS/SbS moiré superlattices.

View Article and Find Full Text PDF

Cantilever-Enhanced Fiber-Optic Photoacoustic Spectrophone for Low-Pressure Gas Detection.

Anal Chem

January 2025

School of Optoelectronic Engineering and Instrumentation Science, Dalian University of Technology, Dalian 116024, Liaoning, China.

A cantilever-enhanced fiber-optic photoacoustic (PA) spectrophone is reported for trace gas detection at a low-pressure environment. A cantilever-based fiber-optic Fabry-Perot (F-P) interferometer (FPI) is utilized for simultaneous measurement of air pressure and PA pressure. Since the cantilever resonance frequency follows air pressure linearly, the fundamental frequency intensity modulation (1-IM) technique is applied to scan the frequency response of the solid PA signal from tube wall absorption for tracking the cantilever resonance frequency in real time.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!