A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Riboflavin/ultraviolet a crosslinking of the paracentral cornea. | LitMetric

Riboflavin/ultraviolet a crosslinking of the paracentral cornea.

Cornea

Institut für Refraktive und Ophthalmo-Chirurgie, Zürich, Switzerland.

Published: February 2013

Purpose: The depth of corneal crosslinking (CXL) does not seem homogeneous within the treatment area but shows a reduction toward the periphery of the cornea. This study was undertaken to investigate this reduction effect and to look for possible solutions.

Methods: Ten corneas were investigated by means of an optical coherence tomography system (SS-100; Tomey, Nagoya, Japan) 1 month after standard CXL (epithelium off, 0.1% riboflavin for 30 minutes, ultraviolet A radiation 365 nm, 3 mW/cm). The depth of the demarcation line was measured as a function of the radial distance from the apex. These curves were compared with a theoretical curve derived from a standard model of photopolymerization.

Results: The CXL depth 3 mm away from the center decreases on average to 65% of the central depth (range: 52%-78%). Polymerization theory predicts this decay, however, underestimates the effect.

Conclusions: The intended depth of CXL using current light sources is achieved only within the central area of the cornea. To provide CXL to the peripheral cornea, the ultraviolet beam either should have an improved intensity profile or may have to be decentered.

Download full-text PDF

Source
http://dx.doi.org/10.1097/ICO.0b013e318269059bDOI Listing

Publication Analysis

Top Keywords

depth
5
cxl
5
riboflavin/ultraviolet crosslinking
4
crosslinking paracentral
4
cornea
4
paracentral cornea
4
cornea purpose
4
purpose depth
4
depth corneal
4
corneal crosslinking
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!