Objectives: Locking plates are the predominant implants used for proximal humerus fractures. Despite a preponderance of good clinical outcomes, failures continue to occur. The purpose of this study was to investigate the failure mechanism of locked proximal humeral plate fixation and its relationship with bone density and screw length.
Methods: Human cadaveric humeri were subjected to cyclic bending loads after an unstable 2-part fracture (Orthopedic Trauma Association classification 11 A-3) was created and stabilized with a locking proximal humeral plate. Acoustic emission (AE) sensors were mounted on the specimens to detect fracture displacement and generation of microcracks. The data were analyzed to evaluate construct failure.
Results: Eight of 10 locking plate constructs in cadaver specimens failed in varus collapse. The primary influences on failure were cancellous bone density and cancellous bone screw length. AE monitoring demonstrated patterns of microcrack progression, predominantly along the inferior screws. The progression trends according to AE were similar to their respective actuator displacement versus time curves.
Conclusions: Cancellous bone density and total cancellous screw depth penetration seem to be critical variables. Although the patients' bone density cannot be controlled, surgeons may decrease the risk of failure by maximizing the length of the screws within the cancellous bone. Analysis of microcrack formation revealed that failures begin at the midportion and tips of the inferior screws and at the bone-plate interface of the inferior screws.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/BOT.0b013e31827934c1 | DOI Listing |
Cardiovasc Diabetol
January 2025
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, No.2 Anzhen Road, Chaoyang District, 100029, Beijing, China.
Introduction: Bone marrow-derived mesenchymal stem cell-derived extracellular vesicles (BMSC-EVs) are widely used for therapeutic purposes in preclinical studies. However, their utility in treating diabetes-associated atherosclerosis remains largely unexplored. Here, we aimed to characterize BMSC-EV-mediated regulation of autophagy and macrophage polarization.
View Article and Find Full Text PDFCalcif Tissue Int
January 2025
University of Pittsburgh, 3860 S. Water St., Pittsburgh, PA, 15203, USA.
Sport participation affects body composition and bone health, but the association between sport, body composition, and bone health in female athletes is complex. We compared areal bone mineral density (aBMD, DXA) and tibial volumetric bone mineral density (vBMD), geometry, microarchitecture, and estimated strength (HR-pQCT) in cross-country runners (n = 22), gymnasts (n = 23) and lacrosse players (n = 35), and investigated associations of total body lean mass (TBLM), team, and their interaction with tibial bone outcomes. Total body (TB), total hip (TH), femoral neck (FN), and lumbar spine (LS) aBMD were higher in gymnasts than runners (p < 0.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Bone Joint, Binzhou Medical University Hospital, No. 661 Huanghe 2nd Road, Binzhou, 256600, China.
This study examines the biocompatibility, osteogenic potential, and effectiveness of polyether ether ketone (PEEK) composites for treating osteonecrosis, seeking to establish a theoretical basis for clinical application. A range of PEEK composite materials, including sulfonated polyether ether ketone (SPEEK), polydopamine-sulfonated polyether ether ketone (SPEEK-PDA), bone-forming peptide-poly-dopamine-sulfonated polyether ether ketone (SPEEK-PDA-BFP), and vascular endothelial growth factor-poly-dopamine-sulfonated polyether ether ketone (SPEEK-PDA-VEGF), were constructed by concentrated sulfuric acid sulfonation, polydopamine modification and grafting of bioactive factors. The experiments involved adult male New Zealand rabbits aged 24-28 weeks and weighing 2.
View Article and Find Full Text PDFJ Biomech
January 2025
Radboudumc, Orthopaedic Research Lab, PO Box 9101, 6500 HB Nijmegen, the Netherlands.
Aseptic loosening is the primary cause of revision in cementless total knee arthroplasty (TKA), emphasizing the importance of strong initial stability for long-term implant success. Pre-clinical evaluations are crucial for understanding implant fixation mechanics and improving implant designs. Finite element (FE) analysis models often use linear elastic bone material models, which do not accurately reflect bone's mechanical behavior.
View Article and Find Full Text PDFJ Bone Joint Surg Am
January 2025
Shriners Children's Northern California, Sacramento, California.
Background: Magnetic resonance imaging (MRI) has not been routinely used for infants with brachial plexus birth injury (BPBI); instead, the decision to operate is based on the trajectory of clinical recovery by 6 months of age. The aim of this study was to develop an MRI protocol that can be performed without sedation or contrast in order to identify infants who would benefit from surgery at an earlier age than the age at which that decision could be made clinically.
Methods: This prospective multicenter NAPTIME (Non-Anesthetized Plexus Technique for Infant MRI Evaluation) study included infants aged 28 to 120 days with BPBI from 3 tertiary care centers.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!