Purpose: This study examined whether there is a difference in external rotation (ER) between type 2 SLAP repairs consisting of anchors placed only posterior to the biceps insertion compared with repairs with an additional anchor placed anterior to the biceps.
Methods: Seven cadaveric shoulders from donors with a mean age of 39.4 years were tested. Type 2 SLAP lesions were created, followed by a 3-anchor repair: a standard repair with 2 anchors posterior to the biceps plus an additional anchor anterior to the biceps. The specimens were placed on a material testing system machine and rotation was measured under a constant torque. The sutures were then removed sequentially from anterior to posterior during testing.
Results: The average ER of the intact shoulder was 115.7° ± 2.6°. After SLAP tear creation and cyclic loading, the ER was 118.5° ± 2.6°, which decreased to 116.5° ± 2.6° after repair. This corresponds to a reduction of 2.0° of ER (P < .0001) with the repair. After release of the anterior anchor, the ER increased to 117.9° ± 2.6°, which corresponds to an increase in shoulder motion of 1.4° of ER (P = .0011). Additional release of the middle anchor, leaving only the posterior anchor intact, resulted in 118.0° ± 2.7° of ER, which corresponds to an increase of only 0.1° of ER (P = .7667).
Conclusions: Following type 2 SLAP repair in the cadaveric shoulder, removing the effect of the anchor anterior to the biceps resulted in a small but statistically significant increase in ER. The anterior anchor had the greatest effect on ER. The presence of 1 or 2 anchors posterior to the biceps did not have a significant effect on rotation.
Clinical Relevance: When performing SLAP repairs on those in whom even a small loss of ER would be detrimental, such as baseball pitchers, avoidance of the use of an anchor anterior to the biceps should be considered.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.arthro.2012.06.021 | DOI Listing |
Proc Natl Acad Sci U S A
January 2025
Department of Psychology, Center for Brain Science, Harvard University, Cambridge, MA 02138.
The hippocampus possesses anatomical differences along its long axis. Here, we explored the functional specialization of the human hippocampal long axis using network-anchored precision functional MRI in two independent datasets (N = 11 and N = 9) paired with behavioral analysis (N = 266 and N = 238). Functional connectivity analyses demonstrated that the anterior hippocampus was preferentially correlated with a cerebral network associated with remembering, while the posterior hippocampus selectively contained a region correlated with a distinct network associated with behavioral salience.
View Article and Find Full Text PDFJ Orthop Case Rep
January 2025
Department of Orthopaedics, University of Toledo Medical Center, Ohio, USA.
Introduction: Bony and ligamentous ankle injuries are some of the most commonly treated injuries by orthopedic surgeons. Open ligamentous ankle injuries without an associated fracture or dislocation are rare and to our knowledge have only sparsely been described in the literature. We present a case and successful treatment of an open lateral ankle injury with capsular rupture and ligamentous damage without fracture or dislocation in a 22-year-old female.
View Article and Find Full Text PDFJ ISAKOS
January 2025
Department of Sports Medicine, Kameda Medical Center, Kamogawa, Japan.
Objectives: We have previously shown that ultrasound-guided repair results in an accurate anchor placement and restores ankle joint stability using cadaveric models. The objective is to assess the safety and clinical outcomes of ultrasound-guided ATFL repair with or without augmentation.
Methods: Forty-nine patients with chronic lateral ankle instability underwent ultrasound-guided ATFL repair with or without augmentation.
JACC Heart Fail
January 2025
The Zena and Michael A. Wiener Cardiovascular Institute, Icahn School of Medicine at Mount Sinai, New York, New York, USA.
Background: Left ventricular (LV) dilatation and extensive scar portend a poor prognosis in heart failure (HF). The Revivent TC system (BioVentrix Inc) is used either during a hybrid transcatheter-surgical or a surgical-only procedure to exclude transmural scar and reduce LV dimensions.
Objectives: The purpose of this study was to examine the safety and efficacy of the Revivent TC® anchor system in patients with HF.
J Clin Med
January 2025
Department of Biomedical Sciences, Humanitas University, Via Rita Levi Montalcini 4, 20072 Pieve Emanuele, Italy.
Arthroscopic rotator cuff repair (RCR) is a common procedure, yet long-term patient-centered outcome studies remain limited. This study aims to evaluate the outcomes of arthroscopic RCR using a single-row metallic anchor technique over a 12-year follow-up, focusing on patient-reported outcomes and potential risk factors. A monocentric cohort study was conducted on patients who underwent complete arthroscopic RCR with a single-row metallic anchor technique from January 2007 to July 2011.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!