This paper evaluates the performance of two large-area position-sensitive solid-state photomultipliers (PS-SSPM) for use in small animal PET detector designs. Both PS-SSPM device designs are 1 cm² in area, the first being a 2 × 2 tiled array of 5 mm × 5 mm PS-SSPMs and the second being a 10 mm × 10 mm continuous PS-SSPM. Signal-to-noise measurements were performed to investigate the optimal operating parameters for each device and to compare the performance of the two PS-SSPM designs. A maximum signal-to-noise ratio of 29.3 was measured for the 5 mm PS-SSPM array and 15.1 for the 10 mm PS-SSPM, both measurements were made at 0 °C and at the optimal bias voltage. The best energy resolution measured with an array of 1.3 mm polished LSO crystals was 16% for the 5 mm PS-SSPM array and 18% for the 10 mm PS-SSPM. The timing properties of both devices were similar, with a best timing resolution (in coincidence with an LSO/PMT detector) of 6.8 ns (range 6.8-8.9 ns) and 7.1 ns (range 7.1-9.6 ns) for the 5 mm PS-SSPM and 10 mm PS-SSPM respectively. The 2 × 2 array of 5 mm PS-SSPMs was able to visually resolve the elements in an 0.5 × 0.5 × 20 mm LYSO scintillator array (unpolished, diffuse reflector) with an average peak-to-valley ratio in the flood histograms of ∼11 indicating clear separation of the crystals. Advantages and drawbacks of PET detector designs using PS-SSPM photodetectors are addressed and comparisons to other small-animal PET detector designs using position-sensitive avalanche photodiodes are made.

Download full-text PDF

Source
http://dx.doi.org/10.1088/0031-9155/57/24/8119DOI Listing

Publication Analysis

Top Keywords

pet detector
12
detector designs
12
ps-sspm array
12
ps-sspm
11
large-area position-sensitive
8
position-sensitive solid-state
8
solid-state photomultipliers
8
small animal
8
animal pet
8
designs ps-sspm
8

Similar Publications

Digital detector PET/CT increases Centiloid measures of amyloid in Alzheimer's disease: A head-to-head comparison of cameras.

J Alzheimers Dis

January 2025

Health and Biosecurity, Commonwealth Scientific and Industrial Research Organisation, Brisbane, QLD, Australia.

Background: The introduction of therapeutics for Alzheimer's disease has led to increased interest in precisely quantifying amyloid-β (Aβ) burden for diagnosis, treatment monitoring, and further clinical research. Recent positron emission tomography (PET) hardware innovations including digital detectors have led to superior resolution and sensitivity, improving quantitative accuracy. However, the effect of PET scanner on Centiloid remains relatively unexplored and is assumed to be minimized by harmonizing PET resolutions.

View Article and Find Full Text PDF

A multiplexing method based on multidimensional readout method.

Phys Med Biol

January 2025

Institute of Biomedical Engineering, Shenzhen Bay Laboratory, Guangqiao Load, Shenzhen, 518132, CHINA.

To develop and validate a novel multidimensional readout method that significantly reduces the number of readout channels in PET detectors while maintaining high spatial and energy performance. Approach: We arranged a 3×3×4 SiPM array in multiple dimensions and employed row/column/layer summation with a resistor-based splitting circuit. We then applied denoising methods to enhance the peak-to-valley ratio in the decoding map, ensuring accurate crystal-position determination.

View Article and Find Full Text PDF

Monolithic U-shaped crystal design for TOF-DOI detectors: a flat top vs. a tapered top.

Biomed Phys Eng Express

January 2025

Advanced Nuclear Medicine Science, National Institute of Radiological Sciences, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, JAPAN, Chiba, 263-8555, JAPAN.

For brain-dedicated positron emission tomography (PET) scanners, depth-of-interaction (DOI) information is essential to achieve uniform spatial resolution across the field-of-view (FOV) by minimizing parallax error. Time-of-flight (TOF) information can enhance the image quality. In this study, we proposed a novel monolithic U-shaped crystal design that had a tapered geometry to achieve good coincidence timing resolution (CTR) and DOI resolution simultaneously.

View Article and Find Full Text PDF

Integrating time-of-flight (ToF) measurements in radiography and computed tomography (CT) enables an approach for scatter rejection in imaging systems that eliminates the need for anti-scatter grids, potentially increasing system sensitivity and image quality. However, present hardware dedicated to the time-correlated measurement of X-rays is limited to a small scale and low density. A switch to highly integrated electronics and detectors is needed to progress towards a medium-scale system capable of acquiring images, while offering a timing resolution below 300 ps FWHM to achieve scatter rejection comparable to current grids.

View Article and Find Full Text PDF

Objectives: Primary pulmonary artery sarcoma (PPAS) is a rare disease with unclear clinical manifestations. Advances in imaging devices have improved diagnostic capabilities, potentially affecting clinical characteristics and overall survival (OS); however, details remain unclear. This study conducted a pooled analysis of case reports and series to analyse the clinical characteristics and OS of PPAS in the era of advanced medical devices.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!