The screw loosening of implant-supported prostheses is a common mechanical failure and is related to several factors as insertion torque and preload. The aim of this study was to evaluate the torque maintenance of retention screws of tapered abutments and cylinders of Morse taper implants submitted to retightening and detorque measurements. Two groups were obtained (n = 12): group I-tapered abutment connected to the implant with titanium retention screw and group II-cylinder with metallic base connected to tapered abutment with titanium retention screw. The detorque values were measured by an analogic torque gauge after 3 minutes of torque insertion. The detorque was measured 10 times for each retention screw of groups I and II, totalizing 120 detorque measurements in each group. Data were submitted to ANOVA and Fisher exact test (P < 0.05). Both groups presented reduced detorque value (P < 0.05) in comparison to the insertion torque in all measurement periods. There was a statistically significant difference (P < 0.05) between the detorque values of the first measurement and the other measurement periods for the abutment screw. However, there was no statistically significant difference (P > 0.05) for the detorque values of all measurement periods for the cylinder screw. In conclusion, the abutment and cylinder screws exhibited torque loss after insertion, which indicates the need for retightening during function of the implant-supported prostheses.

Download full-text PDF

Source
http://dx.doi.org/10.1097/SCS.0b013e318270fe0eDOI Listing

Publication Analysis

Top Keywords

retention screw
12
detorque values
12
measurement periods
12
torque maintenance
8
abutment cylinder
8
cylinder screws
8
morse taper
8
taper implants
8
implant-supported prostheses
8
insertion torque
8

Similar Publications

Optimizing whole grain rice fortification using microwave-assisted screw conveying spraying and drying setup: Exploring solution absorption, gelatinization, and micronutrient retention.

Food Chem

December 2024

Laboratory of Applied Food Chemistry, Microbiology and Process Engineering, Centre for Food Engineering and Technology, Department of Chemical Engineering, Birla Institute of Technology, Mesra, Ranchi, Jharkhand 835215, India. Electronic address:

This study presents a novel gelatinization-induced whole-grain rice fortification (GIWGRF) technology using a microwave-assisted screw conveying spraying and drying setup (MASCSD). The process involves microwave-assisted soaking of pregelatinized rice in a micronutrient solution, followed by steam-assisted gelatinization and drying. Rice with an initial degree of gelatinization (DG) of 58.

View Article and Find Full Text PDF

Introduction: Acute fracture-related infections are challenging problems, affecting up to 20% of orthopaedic trauma patients. High recurrence rates, secondary surgeries, and rehospitalizations lead to increased healthcare costs and are major burdens to patients. Bacteriophage therapy offers a potential alternative treatment option to address these challenges.

View Article and Find Full Text PDF

Effect of reactive extrusion processing conditions on the production of potato-resistant starch and its use as an additive in yogurt.

Int J Biol Macromol

December 2024

Posgrado en Ciencia y Tecnología de Alimentos, Facultad de Ciencias Químico-Biológicas, Universidad Autónoma de Sinaloa, Cd. Universitaria, Av. de las Américas y Josefa Ortiz S/N, 80010 Culiacán, Sinaloa, México. Electronic address:

Starch has multiple uses in the food industry as a stabilizer, adhesive, gelling agent, thickener, and water retention agent. Nonetheless, native starch presents limitations that restrict its applications. Thus, starch can be chemically modified by reactive extrusion (REX) to overcome these disadvantages.

View Article and Find Full Text PDF

Rationale: Current literature describes only 2 cases combining miniscrew-assisted rapid palatal expansion (MARPE) with lingual appliances. These cases require 2 impressions, 1 before and 1 after palatal expansion, to ensure accurate lingual appliance placement, potentially increasing treatment time and cost. This case report aimed to demonstrate a modified workflow of combining MARPE and lingual appliances in managing an adult patient with anteroposterior and transversal discrepancies, requiring only a single digital impression for both fabrication and positioning.

View Article and Find Full Text PDF

Background: Fractures of thoracolumbar spine in the field of ankylosing diseases such as ankylosing spondylitis (AS) and diffuse idiopathic skeletal hyperostosis (DISH) can by surgically treated with miniinvasive posterior transpedicular fixation. The exact length of implant is the subject of several studies. In our study, we retrospectively evaluated the treatment of B3 fractures of the ankylosed thoracolumbar spine with use a shorter versus longer implant, always with 8 screws.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!