AI Article Synopsis

  • Reliable immobilization of bioreceptors is essential for developing efficient biosensors that can analyze human samples without pre-processing.
  • An optimized method for covalently modifying the sensor's surface was created using a carboxyl water-soluble silane, which prevents organic waste and helps form compact monolayers.
  • Two techniques, in-flow patterning and microcontact printing, were used to link bioreceptors to the sensor, with microcontact printing showing slightly better performance for real-time immunosensing of specific proteins.

Article Abstract

Reliable immobilization of bioreceptors over any sensor surface is the most crucial step for achieving high performance, selective and sensitive biosensor devices able to analyze human samples without the need of previous processing. With this aim, we have implemented an optimized scheme to covalently biofunctionalize the sensor area of a novel nanophotonic interferometric biosensor. The proposed method is based on the ex-situ silanization of the silicon nitride transducer surface by the use of a carboxyl water soluble silane, the carboxyethylsilanetriol sodium salt (CTES). The use of an organosilane stable in water entails advantages in comparison with usual trialkoxysilanes such as avoiding the generation of organic waste and leading to the assembly of compact monolayers due to the high dielectric constant of water. Additionally, cross-linking is prevented when the conditions (e.g. immersion time, concentration of silane) are optimized. This covalent strategy is followed by the bioreceptor linkage on the sensor area surface using two different approaches: an in-flow patterning and a microcontact printing using a biodeposition system. The performance of the different bioreceptor layers assembled is compared by the real-time and label-free immunosensing of the proteins BSA/mAb BSA, employed as a model molecular pair. Although the results demonstrated that both strategies provide the biosensor with a stable biological interface, the performance of the bioreceptor layer assembled by microcontact printing slightly improves the biosensing capabilities of the photonic biosensor.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jcis.2012.10.040DOI Listing

Publication Analysis

Top Keywords

sensor area
8
microcontact printing
8
performance bioreceptor
8
comparative study
4
study in-flow
4
in-flow micro-patterning
4
micro-patterning biofunctionalization
4
biofunctionalization protocols
4
protocols nanophotonic
4
nanophotonic silicon-based
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!