Predictive value of pulse pressure variation for fluid responsiveness in septic patients using lung-protective ventilation strategies.

Br J Anaesth

Departamento de Anestesiologia, Dor e Terapia Intensiva, Universidade Federal de São Paulo, Rua Napoleão de Barros 715-5° andar, 04024-900 São Paulo, SP, Brazil.

Published: March 2013

Background: The applicability of pulse pressure variation (ΔPP) to predict fluid responsiveness using lung-protective ventilation strategies is uncertain in clinical practice. We designed this study to evaluate the accuracy of this parameter in predicting the fluid responsiveness of septic patients ventilated with low tidal volumes (TV) (6 ml kg(-1)).

Methods: Forty patients after the resuscitation phase of severe sepsis and septic shock who were mechanically ventilated with 6 ml kg(-1) were included. The ΔPP was obtained automatically at baseline and after a standardized fluid challenge (7 ml kg(-1)). Patients whose cardiac output increased by more than 15% were considered fluid responders. The predictive values of ΔPP and static variables [right atrial pressure (RAP) and pulmonary artery occlusion pressure (PAOP)] were evaluated through a receiver operating characteristic (ROC) curve analysis.

Results: Thirty-four patients had characteristics consistent with acute lung injury or acute respiratory distress syndrome and were ventilated with high levels of PEEP [median (inter-quartile range) 10.0 (10.0-13.5)]. Nineteen patients were considered fluid responders. The RAP and PAOP significantly increased, and ΔPP significantly decreased after volume expansion. The ΔPP performance [ROC curve area: 0.91 (0.82-1.0)] was better than that of the RAP [ROC curve area: 0.73 (0.59-0.90)] and pulmonary artery occlusion pressure [ROC curve area: 0.58 (0.40-0.76)]. The ROC curve analysis revealed that the best cut-off for ΔPP was 6.5%, with a sensitivity of 0.89, specificity of 0.90, positive predictive value of 0.89, and negative predictive value of 0.90.

Conclusions: Automatized ΔPP accurately predicted fluid responsiveness in septic patients ventilated with low TV.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC9121394PMC
http://dx.doi.org/10.1093/bja/aes398DOI Listing

Publication Analysis

Top Keywords

fluid responsiveness
16
responsiveness septic
12
septic patients
12
[roc curve
12
curve area
12
pulse pressure
8
pressure variation
8
lung-protective ventilation
8
ventilation strategies
8
patients ventilated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!