Purpose: Compared with daily disposable wear schedule, continuous wear (CW) or extended wear of contact lenses has been associated with an increased risk of developing an ocular infection. Proof-of-principle studies were conducted to investigate the impact of daily replacement of lenses on the rate of contact lens-related ocular adverse events (AEs) during 30-night CW.

Methods: A total of 215 subjects were dispensed with silicone hydrogel lenses on a 30-night CW schedule but replaced lenses daily either each night before sleeping (n = 178 eyes) or each morning after waking (n = 252 eyes). Scheduled clinic visits were conducted at 1 week and 1 month. Neophytes were required to complete 1 week of daily wear before commencing CW. A historical control (n = 191 eyes) using the same site, subject demographics, and visit schedule but monthly lens replacement was used for AE rates.

Results: Logistic regression analysis showed a significant reduction in mechanical AEs (0.8 vs 5.2%, p = 0.01) and overall AEs (inflammatory and mechanical events) (4.0 vs 8.9%, p = 0.04) when lenses were replaced each morning compared with being replaced monthly. Estimation of handling-related lens contamination of unworn lenses in a subgroup of subjects showed isolation of Staphylococcus aureus from the lenses of 35% of subjects, and 65% of subjects had more than 1000 colony-forming units per lens of gram-positive bacterial contamination.

Conclusions: Morning lens replacement during CW reduced mechanical and overall ocular AEs. Replacing lenses at night had no beneficial effects perhaps because the benefit of a fresh lens at night might be partially negated by contamination of the contact lens caused by lens handling before overnight eye closure. Contact lens wearers on an extended wear or CW schedule should be advised to minimize lens handling before sleep to reduce the risk of complications.

Download full-text PDF

Source
http://dx.doi.org/10.1097/OPX.0b013e31827731acDOI Listing

Publication Analysis

Top Keywords

lens replacement
12
lens
9
ocular adverse
8
adverse events
8
wear schedule
8
extended wear
8
lenses
8
contact lens
8
lens handling
8
wear
6

Similar Publications

Quarter of a century of contact lens prescribing trends in Australia (2000-2024).

Clin Exp Optom

January 2025

Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.

Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.

Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.

Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.

View Article and Find Full Text PDF

The design of the prosthetic replacement of the ocular surface ecosystem (PROSE) device allows it to serve as a novel drug delivery system. In this article, we describe the off-label administration of amphotericin B and cenegermin by instillation in the PROSE device reservoir for the treatment of Candida keratitis in the setting of a persistent epithelial defect.

View Article and Find Full Text PDF

Background: In the last years, the Cor-Knot device has been increasingly used in heart valve surgery. Our aim was to investigate the incidence of valvular complications in patients who underwent valvular surgery using the Cor-Knot device in multicentric cohorts at one-year follow-up.

Methods: Three hundred and sixty-eight patient underwent heart valve repair or replacement surgery using automated titanium suture fasteners in four cardiothoracic surgery departments between September 2018 and January 2020.

View Article and Find Full Text PDF

: The objective of this study was to examine the trend of treatment zone (TZ) decentration over 12 months of orthokeratology (OK) wear using two Corneal Refractive Therapy (CRT) lens designs: standard (STD) and dual axis (DA). : A prospective, randomized, longitudinal study was conducted at the Optometry Clinic of the Complutense University of Madrid. Subjects were randomly fitted with an STD design or DA design in one of the eyes.

View Article and Find Full Text PDF

Fast Proxy Centers for the Jeffreys Centroid: The Jeffreys-Fisher-Rao Center and the Gauss-Bregman Inductive Center.

Entropy (Basel)

November 2024

Sony Computer Science Laboratories, Tokyo 141-0022, Japan.

The symmetric Kullback-Leibler centroid, also called the Jeffreys centroid, of a set of mutually absolutely continuous probability distributions on a measure space provides a notion of centrality which has proven useful in many tasks, including information retrieval, information fusion, and clustering. However, the Jeffreys centroid is not available in closed form for sets of categorical or multivariate normal distributions, two widely used statistical models, and thus needs to be approximated numerically in practice. In this paper, we first propose the new Jeffreys-Fisher-Rao center defined as the Fisher-Rao midpoint of the sided Kullback-Leibler centroids as a plug-in replacement of the Jeffreys centroid.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!