Background: Many adults with repaired tetralogy of Fallot have had prior Blalock-Taussig shunts. These shunts may theoretically hinder growth and development of the ipsilateral arm.

Methods: We prospectively enrolled consecutive patients with tetralogy of Fallot in a cross-sectional study to measure arm length and assess handgrip strength. Bilateral handgrip strength was quantified by a dynamometer in a standing position after instructing patients to clench each hand tightly in succession. The maximum force achieved, in kilograms, was measured.

Results: A total of 80 consecutive adults with tetralogy of Fallot, aged 36.0 ± 12.5 years, 49% female, were prospectively enrolled. Thirty-eight (47.5%) patients had prior Blalock-Taussig shunts at a median age of 1.0 year. Twenty-one (55.3%) were left-sided and 23 (60.5%) were classic shunts. All but six patients with right-sided shunts and one without a prior shunt were right-handed. The shunts were present for a median of 4.0 years prior to takedown during corrective surgery. The arm ipsilateral to the shunt was significantly shorter than the contralateral arm (71.5 ± 6.1 versus 73.6 ± 5.6 cm, P<0.0001). Handgrip strength was significantly weaker on the ipsilateral versus contralateral side (median [IQR], 26.5 [14.0-41.5] versus 31.0 [18.0-46.0] kg, P<0.0001) and the ipsilateral-to-contralateral handgrip ratio was lower with classic versus modified shunts (median [IQR], 1.05 [1.02-1.14] versus 1.19 [1.07-1.33] kg, P=0.0541).

Conclusion: In patients with tetralogy of Fallot, Blalock-Taussig shunts may impair normal development of the ipsilateral arm with repercussions in adulthood that include shorter limb length and reduced handgrip strength. These changes are most pronounced in patients with classic end-to-side anastomoses.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2012.10.034DOI Listing

Publication Analysis

Top Keywords

tetralogy fallot
16
blalock-taussig shunts
12
adults repaired
8
repaired tetralogy
8
prior blalock-taussig
8
prospectively enrolled
8
handgrip strength
8
shunts median
8
shunts
7
impaired arm
4

Similar Publications

Background: Tetralogy of Fallot is one of the critical congenital heart defects needing intervention within the first year of life.

Objective: This review aims to systematically assess the prevalence of Tetralogy of Fallot among children and adolescents with congenital heart defects in Sub-Saharan Africa from January 2000 to January 2024.

Methods: All original observational studies focused on children and adolescent population diagnosed with congenital heart defects within Sub-Saharan Africa; reported the primary outcome of interest were included.

View Article and Find Full Text PDF

CHDs affecting the right ventricular outflow tract often require repeated surgical or transcatheter interventions due to pulmonary insufficiency or stenosis. This study presents percutaneous implantation of large self-expanding valves in patients with complex right ventricular outflow tract anatomy after prior pulmonary branch stenting.

View Article and Find Full Text PDF

Background: Ventricular tachycardia (VT) substrate characteristics before transcatheter pulmonary valve replacement (TPVR) in repaired tetralogy of Fallot (rTOF) are unknown.

Objectives: In this study, the authors sought to evaluate substrates for sustained monomorphic VT before TPVR in rTOF.

Methods: Retrospective (2017 to 2021) and prospective (commencing 2021) rTOF patients with native right ventricular outflow tract referred for electrophysiology study (EPS) before TPVR were included.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!