Exhaled breath condensate pH in mechanically ventilated patients.

Med Intensiva

Neumonología, Universidad Nacional de Rosario, Hospital Escuela "Eva Perón", Argentina. Electronic address:

Published: December 2013

Objectives: In this prospective clinical trial we aimed to answer if spontaneous exhaled breath condensate (EBC) in the trap of the expiratory arm of the ventilator could replace EBC collected by coolant chamber standardized with Argon as an inert gas. Second, if EBC pH could predict ventilator associated pneumonia (VAP) and mortality.

Patients: We included 34 critically ill patients (males = 26), aged = 54.85 ± 19.86 (mean ± SD) yrs, that required mechanical ventilation due to non-pulmonary direct cause (APACHE II score = 23.58 ± 14.7; PaO(2)/FiO(2) = 240.00 ± 98.29).

Setting: ICU with 9 beds from a regional teaching hospital.

Intervention And Results: The patients were followed up until development of VAP, successful weaning or death. There were significant differences between mean EBC pH from the 4 procedures with the exception of spontaneous EBC de-aerated with Argon (n = 79; 6.74 ± 0.28) and coolant chamber deaerated with Argon (n = 79; 6.70 ± 0.36; p = NS by Tukey's Multiple Comparison Test). However, none of the procedures were extrapolated between each other according to Bland & Altman method. The mean EBC pH from the trap without Argon was 6.50 ± 0.28. From the total of 34 patients, 22 survived and were discharged and 12 patients died in the ICU.

Conclusion: Spontaneous EBC pH could not be extrapolated to EBC pH from coolant chamber and it did not change in subjects who dead, neither subject with VAP in comparison with baseline data. The lack of other biomarker in EBC and the lack of a control group determinate the need for further studies in this setting.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.medin.2012.10.002DOI Listing

Publication Analysis

Top Keywords

coolant chamber
12
ebc
9
exhaled breath
8
breath condensate
8
ebc trap
8
spontaneous ebc
8
patients
5
condensate mechanically
4
mechanically ventilated
4
ventilated patients
4

Similar Publications

Bioinspired thermally conducting packaging for heat management of high performance electronic chips.

Commun Eng

January 2025

Guangdong Provincial Key Laboratory of Optical Information Materials and Technology & Institute of Electronic Paper Displays, South China Academy of Advanced Optoelectronics, South China Normal University, Guangzhou, 510006, PR China.

Conventional electronic chip packaging generates a huge thermal resistance due to the low thermal conductivity of the packaging materials that separate chip dies and coolant. Here we propose and fabricate a closed high-conducting heat chip package based on passive phase change, using silicon carbide which is physically and structurally compatible with chip die materials. Our "chip on vapor chamber" (CoVC) concept realizes rapid diffusion of hot spots, and eliminates the high energy consumption of refrigeration ordinarily required for heat management.

View Article and Find Full Text PDF

This article investigates the convective thermal and solutal exchange from the active walls of a trapezium chamber which is filled with multi-walled carbon nanotubes (MWCNT)-silicon dioxide (SiO)-ethylene glycol-water hybrid nano-coolant. The hybrid nano-coolant exhibits non-Newtonian shear-thinning rheology and is modeled by the power-law viscosity as per an exploratory report. The convection is generated by both the thermal and solutal buoyancy forces in the presence of a magnetic field.

View Article and Find Full Text PDF

The Effect of Water Coolant and Bur Type on Pulp Temperature When Removing Tooth Structure and Restorative Dental Materials.

Oper Dent

January 2024

*Paul V. Abbott, BDSc, MDS, DDSc, FRACDS(Endo), emeritus professor, UWA Dental School, The University of Western Australia, Nedlands, WA, Australia.

Objective: The aim was to compare intrapulp temperature (IPT) changes when flat-fissure diamond burs and pear-shaped tungsten carbide burs were used to cut tooth structure, amalgam, and composite resin with and without water coolant.

Methods: Thermocouples were inserted into the pulp chamber of extracted intact mandibular molars. The thermocouples were connected to an electronic thermometer that detects temperature every second to an accuracy of 0.

View Article and Find Full Text PDF

Mitigation of PWR fuel assembly vibrations using bio-inspired nozzles.

Sci Rep

November 2023

Framatome Inc., 3315 Old Forest Road, Lynchburg, VA, 24506, USA.

Jet flows injected in a transverse flow need rapid and effective mixing for various applications ranging from medicine injection into bloodstreams to nuclear pressurized water reactors (PWRs). Inspired by marine organisms, spiral snails, and sharks, bio-inspired nozzles are proposed and experimentally investigated to explore their advantages in suppressing nuclear fuel assembly vibrations. It has been observed that a combination of axial flow and jet cross-flow causes vibrations of fuel rods and potential wear at spacer grid supports.

View Article and Find Full Text PDF

The design of popular disposable electronic cigarettes (ECs) was analyzed, and the concentrations of WS-23, a synthetic coolant, in EC fluids were determined for 22 devices from 4 different brands. All products contained WS-23 in concentrations that ranged from 1.0 to 40.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!